Literature DB >> 1762013

Induction and prevention of pin loosening in external fixation: an in vivo study on sheep tibiae.

C Hyldahl1, S Pearson, S Tepic, S M Perren.   

Abstract

In external fixation of fractures, pin loosening is a major concern. Preloading the pins is generally done to ensure their stability within the bone cortex. The effect of radial preload and bending preload in reducing resorption at the pin/bone interface was tested. Schanz screws were fixed to live sheep tibiae using a pneumatically operated external fixator frame. Evaluation was based on radiological observation and fluorochrome histology using sequential labels. Though not completely absent, bone resorption was minimal in the radial preload group, compared with the two other groups. More important, the bone-to-pin contact surface in the radial preload group was found to be almost intact after 5 weeks. In this study, radial preload appears to be superior to bending preload in terms of minimizing the problems of pin loosening.

Entities:  

Mesh:

Year:  1991        PMID: 1762013     DOI: 10.1097/00005131-199112000-00017

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  8 in total

1.  Computational simulations of stress shielding and bone resorption around existing and computer-designed orthopaedic screws.

Authors:  A Gefen
Journal:  Med Biol Eng Comput       Date:  2002-05       Impact factor: 2.602

2.  Microstructural analysis of implant-bone interface of hydroxyapatite-coated and uncoated Schanz screws.

Authors:  M Cimerman; A Cör; M Ceh; A Kristan; J Pizem; M Tonin
Journal:  J Mater Sci Mater Med       Date:  2005-07       Impact factor: 3.896

3.  Effects of Ti2448 half-pin with low elastic modulus on pin loosening in unilateral external fixation.

Authors:  Kai Zheng; Xiaokang Li; Jun Fu; Xiangli Fan; Pan Wang; Yulin Hao; Shujun Li; Hongbin Fan; Zheng Guo
Journal:  J Mater Sci Mater Med       Date:  2011-04-13       Impact factor: 3.896

4.  Enhanced biocompatibility and osseointegration of calcium titanate coating on titanium screws in rabbit femur.

Authors:  Zi-Li Wang; Rong-Zhen He; Bin Tu; Xu Cao; Jin-Shen He; Han-Song Xia; Chi Liang; Min Zou; Song Wu; Zhen-Jun Wu; Kun Xiong
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

5.  Stability with unilateral external fixation in the tibia.

Authors:  N Giotakis; B Narayan
Journal:  Strategies Trauma Limb Reconstr       Date:  2007-04

6.  Effect of the starting point of half-pin insertion on the insertional torque of the pin at the tibia.

Authors:  Sung Jae Kim; Sung Hwan Kim; Young Hwan Kim; Yong Min Chun
Journal:  Yonsei Med J       Date:  2015-01       Impact factor: 2.759

7.  Longitudinal intravital imaging of the femoral bone marrow reveals plasticity within marrow vasculature.

Authors:  David Reismann; Jonathan Stefanowski; Robert Günther; Asylkhan Rakhymzhan; Romano Matthys; Reto Nützi; Sandra Zehentmeier; Katharina Schmidt-Bleek; Georg Petkau; Hyun-Dong Chang; Sandra Naundorf; York Winter; Fritz Melchers; Georg Duda; Anja E Hauser; Raluca A Niesner
Journal:  Nat Commun       Date:  2017-12-18       Impact factor: 14.919

8.  Finite element analysis of the equivalent stress distribution in Schanz screws during the use of a femoral fracture distractor.

Authors:  Vincenzo Giordano; Alexandre Leme Godoy-Santos; William Dias Belangero; Robinson Esteves Santos Pires; Pedro José Labronici; Hilton Augusto Koch
Journal:  Rev Bras Ortop       Date:  2017-07-24
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.