Literature DB >> 17611860

Mechanical evaluation of a new minimally invasive device for stabilization of proximal humeral fractures in elderly patients: a cadaver study.

Georg N Duda1, Devakara R Epari, Reto Babst, Simon M Lambert, Romano Matthys, Norbert P Südkamp.   

Abstract

BACKGROUND: Treatment of proximal humerus fractures in elderly patients is challenging because of reduced bone quality. We determined the in vitro characteristics of a new implant developed to target the remaining bone stock, and compared it with an implant in clinical use.
METHODS: Following osteotomy, left and right humeral pairs from cadavers were treated with either the Button-Fix or the Humerusblock fixation system. Implant stiffness was determined for three clinically relevant cases of load: axial compression, torsion, and varus bending. In addition, a cyclic varus-bending test was performed.
RESULTS: We found higher stiffness values for the humeri treated with the ButtonFix system--with almost a doubling of the compression, torsion, and bending stiffness values. Under dynamic loading, the ButtonFix system had superior stiffness and less K-wire migration compared to the Humerusblock system.
INTERPRETATION: When compared to the Humerusblock design, the ButtonFix system showed superior biomechanical properties, both static and dynamic. It offers a minimally invasive alternative for the treatment of proximal humerus fractures.

Entities:  

Mesh:

Year:  2007        PMID: 17611860     DOI: 10.1080/17453670710014031

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  3 in total

1.  The calcar screw in angular stable plate fixation of proximal humeral fractures--a case study.

Authors:  Georg Osterhoff; Christian Ossendorf; Guido A Wanner; Hans-Peter Simmen; Clément M Werner
Journal:  J Orthop Surg Res       Date:  2011-09-24       Impact factor: 2.359

2.  The effect of long calcar screws on the primary stability of 3-part, varus impacted proximal humeral fractures compared to short calcar screws: a real fracture simulation study.

Authors:  Nadine Ott; Michael Hackl; Andreas Prescher; Martin Scaal; Fabian Lanzerath; Lars Peter Müller; Kilian Wegmann
Journal:  Arch Orthop Trauma Surg       Date:  2022-05-30       Impact factor: 3.067

Review 3.  Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review.

Authors:  Ali Jabran; Chris Peach; Lei Ren
Journal:  Biomed Eng Online       Date:  2018-04-27       Impact factor: 2.819

  3 in total