Literature DB >> 17608740

Bone level changes at axial- and non-axial-positioned implants supporting fixed partial dentures. A 5-year retrospective longitudinal study.

Theofilos Koutouzis1, Jan L Wennström.   

Abstract

AIM: The aim of this study was to retrospectively analyze the potential influence of implant inclination on marginal bone loss at freestanding, implant-supported, fixed partial dentures (FPDs) over a 5-year period of functional loading.
MATERIAL AND METHODS: The material comprised 38 periodontally treated, partially dentate patients with a total of 42 free-standing FPDs supported by implants of the Astra Tech System. Mesio-distal inclination of the implants in relation to a vertical axis perpendicular to the occlusal plane was measured with a protractor on standardized photographs of the master cast. The two tail quartiles of the distribution of the implants with regard to the implant inclination were defined as axial-positioned (mean 2.4 degrees; range 0-4 degrees) and non-axial-positioned implants (mean 17.1 degrees; range 11-30 degrees), respectively. For FPDs supported by two implants, both the mesial-distal and buccal-lingual inter-implant inclination was measured. The primary outcome variable was change in peri-implant bone level from the time of FPD placement to the 5-year follow-up examination. Comparison between axial- and non-axial-positioned implants was performed by the use of a Mann-Whitney U-test. Spearman's correlation analysis was used to analyze relationships between inter-implant inclination (mesial-distal and buccal-lingual) and 5-year bone level change on the FPD level.
RESULTS: The 5-year mean bone level change amounted to 0.4 mm (SD 0.97) for the axial and 0.5 mm (0.95) for non-axial-positioned implants (P>0.05). For the FPDs supported by two implants, the mean inter-implant inclination was 9.2 degrees (1-36 degrees) in the mesial-distal direction and 6.7 degrees (0-24 degrees) in the buccal-lingual direction. Correlation analysis revealed lack of statistically significant correlation between inter-implant inclination (mesial-distal and buccal-lingual) and 5-year bone level change (r=-0.19 and r=-0.32, respectively).
CONCLUSION: The study failed to support the hypothesis that implant inclination has an effect on peri-implant bone loss.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17608740     DOI: 10.1111/j.1600-0501.2007.01386.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  8 in total

Review 1.  Clinical success between tilted and axial implants in edentulous maxilla: A systematic review and meta-analysis.

Authors:  Shruti Parthiv Mehta; Priyanka Vaibhav Sutariya; Mansoorkhan Rafikahmed Pathan; Hemil Hitesh Upadhyay; Surbhi Ravi Patel; Nidhi Dhaval Gupta Kantharia
Journal:  J Indian Prosthodont Soc       Date:  2021 Jul-Sep

2.  Peri-Implant Behavior of Sloped Shoulder Dental Implants Used for All-On-Four Protocols: An Histomorphometric Analysis in Dogs.

Authors:  Jose Luis Calvo Guirado; Aldo Fabian Lucero-Sánchez; Ana Boquete Castro; Marcus Abboud; Sergio Gehrke; Manuel Fernández Dominguez; Rafael Arcesio Delgado Ruiz
Journal:  Materials (Basel)       Date:  2018-01-12       Impact factor: 3.623

3.  Comparison of digital protocols for the measurement of peri-implant marginal bone loss.

Authors:  David Peñarrocha-Oltra; Ivan Palau; Guillermo Cabanes; Beatriz Tarazona; Maria Peñarrocha-Diago
Journal:  J Clin Exp Dent       Date:  2018-12-01

4.  In-vitro fatigue and fracture performance of three different ferrulized implant connections used in fixed prosthesis.

Authors:  Saverio Cosola; Paolo Toti; Enrico Babetto; Ugo Covani; Miguel Peñarrocha-Diago; David Peñarrocha-Oltra
Journal:  J Dent Sci       Date:  2020-08-27       Impact factor: 2.080

Review 5.  Implant Bio-mechanics for Successful Implant Therapy: A Systematic Review.

Authors:  Khaled Mosfer Alzahrani
Journal:  J Int Soc Prev Community Dent       Date:  2020-11-24

6.  Peri-implant health, clinical outcome and patient-centred outcomes of implant-supported overdentures in the mandible and the maxilla.

Authors:  David Offord; Grant Mathieson; Nicola Kingsford; Carine Matthys; Maarten Glibert; Hugo De Bruyn
Journal:  BDJ Open       Date:  2017-09-08

7.  Three-Dimensional Evaluation of Implant Positioning in the Maxillary Sinus Septum: A Retrospective Study.

Authors:  Eliza Dragan; Odri A Guillaume; Danisia Haba; Raphael Olszewski
Journal:  Med Sci Monit       Date:  2015-09-08

8.  Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study.

Authors:  Moustafa Abdou Elsyad; Fathi Abo Setta; Ahmed Samir Khirallah
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.