Literature DB >> 17606088

Variations in pulse oximetry plethysmographic waveform amplitude induced by passive leg raising in spontaneously breathing volunteers.

Samuel Delerme1, Robin Renault, Yannick Le Manach, Virginie Lvovschi, Mouhssine Bendahou, Bruno Riou, Patrick Ray.   

Abstract

PURPOSE: Noninvasive methods that could predict preload responsiveness are lacking. Our objective was to evaluate variations in pulse oximetry plethysmographic (POP) waveform amplitude (deltaPOP) induced by passive leg raising (PLR).
METHODS: We attached a pulse oximeter to the middle finger of 25 spontaneously breathing volunteers at several time points: baseline (ie, semirecumbent position), during PLR at 60 degrees while each subject's trunk was lowered in a supine position at 1 minute, and after putting the patient back in the semirecumbent position (5-minute rest). Heart rate, noninvasive arterial pressures (mean arterial pressure and pulse pressure), maximal POP (POPmax), minimal POP (POPmin), and deltaPOP defined as [POPmax - POPmin]/[(POPmax + POPmin)/2] were recorded using a monitor.
RESULTS: Heart rate, mean arterial pressure, pulse pressure, POPmax, and POPmin values were not different at baseline, during PLR at 1 minute, and after the 5-minute rest (repeated-measures analysis of variance). The median deltaPOP significantly decreased from 16% (95% confidence interval = 11%-23%) to 11% (95% confidence interval = 8%-14%) (P < .05) and then increased to 13% (95% confidence interval = 10%-21%) after the 5-minute rest (P = nonsignificant).
CONCLUSION: Passive leg raising induces a significant decrease in deltaPOP among spontaneously breathing volunteers.

Entities:  

Mesh:

Year:  2007        PMID: 17606088     DOI: 10.1016/j.ajem.2006.11.035

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  12 in total

1.  Analysis of plethysmographic waveform changes induced by beach chair positioning under general anesthesia.

Authors:  Richard Zhu; Gourg Atteya; Kirk H Shelley; David G Silverman; Aymen A Alian
Journal:  J Clin Monit Comput       Date:  2014-01-14       Impact factor: 2.502

Review 2.  Functional hemodynamic monitoring.

Authors:  Michael R Pinsky
Journal:  Crit Care Clin       Date:  2015-01       Impact factor: 3.598

Review 3.  Assessment of volume status and fluid responsiveness in the emergency department: a systematic approach.

Authors:  C Maurer; J Y Wagner; R M Schmid; B Saugel
Journal:  Med Klin Intensivmed Notfmed       Date:  2015-12-16       Impact factor: 0.840

4.  Critically ill patients in emergency department may be characterized by low amplitude and high variability of amplitude of pulse photoplethysmography.

Authors:  Jussi Pirneskoski; Veli-Pekka Harjola; Petri Jeskanen; Lari Linnamurto; Simo Saikko; Jouni Nurmi
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2013-06-24       Impact factor: 2.953

5.  Impact of norepinephrine on the relationship between pleth variability index and pulse pressure variations in ICU adult patients.

Authors:  Matthieu Biais; Vincent Cottenceau; Laurent Petit; Françoise Masson; Jean-François Cochard; François Sztark
Journal:  Crit Care       Date:  2011-07-12       Impact factor: 9.097

6.  Pulse oximetry-derived respiratory rate in general care floor patients.

Authors:  Paul S Addison; James N Watson; Michael L Mestek; James P Ochs; Alberto A Uribe; Sergio D Bergese
Journal:  J Clin Monit Comput       Date:  2014-05-06       Impact factor: 2.502

7.  The assessment of circulating volume using inferior vena cava collapse index and carotid Doppler velocity time integral in healthy volunteers: a pilot study.

Authors:  Tom Peachey; Andrew Tang; Elinor C Baker; Jason Pott; Yonathan Freund; Tim Harris
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-09-02       Impact factor: 2.953

8.  Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers.

Authors:  Geoffray Keller; Emmanuel Cassar; Olivier Desebbe; Jean-Jacques Lehot; Maxime Cannesson
Journal:  Crit Care       Date:  2008-03-06       Impact factor: 9.097

9.  Increasing signal processing sophistication in the calculation of the respiratory modulation of the photoplethysmogram (DPOP).

Authors:  Paul S Addison; Rui Wang; Alberto A Uribe; Sergio D Bergese
Journal:  J Clin Monit Comput       Date:  2014-09-11       Impact factor: 2.502

10.  Calculation of the Respiratory Modulation of the Photoplethysmogram (DPOP) Incorporating a Correction for Low Perfusion.

Authors:  Paul S Addison; Rui Wang; Scott J McGonigle; Alberto A Uribe; Sergio D Bergese
Journal:  Anesthesiol Res Pract       Date:  2014-08-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.