Literature DB >> 17603130

Validation of power measurement techniques in dynamic lower body resistance exercises.

Prue Cormie1, Jeffrey M McBride, Grant O McCaulley.   

Abstract

The objective of this study was to investigate the validity of power measurement techniques utilizing various kinematic and kinetic devices during the jump squat (JS), squat (S) and power clean (PC). Ten Division I male athletes were assessed for power output across various intensities: 0, 12, 27, 42, 56, 71, and 85% of one repetition maximum strength (1RM) in the JS and S and 30, 40, 50, 60, 70, 80, and 90% of 1RM in the PC. During the execution of each lift, six different data collection systems were utilized; (1) one linear position transducer (1-LPT); (2) one linear position transducer with the system mass representing the force (1-LPT+MASS); (3) two linear position transducers (2-LPT); (4) the force plate (FP); (5) one linear position transducer and a force plate (1-LPT+FP); (6) two linear position transducers and a force place (2-LPT+FP). Kinetic and kinematic variables calculated using the six methodologies were compared. Vertical power, force, and velocity differed significantly between 2-LPT+FP and 1-LPT, 1-LPT+MASS, 2-LPT, and FP methodologies across various intensities throughout the JS, S, and PC. These differences affected the load-power relationship and resulted in the transfer of the optimal load to a number of different intensities. This examination clearly indicates that data collection and analysis procedures influence the power output calculated as well as the load-power relationship of dynamic lower body movements.

Mesh:

Year:  2007        PMID: 17603130     DOI: 10.1123/jab.23.2.103

Source DB:  PubMed          Journal:  J Appl Biomech        ISSN: 1065-8483            Impact factor:   1.833


  28 in total

1.  Effect of inter-repetition rest on ratings of perceived exertion during multiple sets of the power clean.

Authors:  Justin P Hardee; Marcus M Lawrence; Alan C Utter; N Travis Triplett; Kevin A Zwetsloot; Jeffrey M McBride
Journal:  Eur J Appl Physiol       Date:  2012-01-04       Impact factor: 3.078

Review 2.  Body mass maximizes power output in human jumping: a strength-independent optimum loading behavior.

Authors:  Slobodan Jaric; Goran Markovic
Journal:  Eur J Appl Physiol       Date:  2013-08-13       Impact factor: 3.078

3.  A low-cost contact system to assess load displacement velocity in a resistance training machine.

Authors:  Bernat Buscà; Anna Font
Journal:  J Sports Sci Med       Date:  2011-09-01       Impact factor: 2.988

4.  The Optimal Load for Maximal Power Production During Lower-Body Resistance Exercises: A Meta-Analysis.

Authors:  Marco A Soriano; Pedro Jiménez-Reyes; Matthew R Rhea; Pedro J Marín
Journal:  Sports Med       Date:  2015-08       Impact factor: 11.136

Review 5.  Weightlifting pulling derivatives: rationale for implementation and application.

Authors:  Timothy J Suchomel; Paul Comfort; Michael H Stone
Journal:  Sports Med       Date:  2015-06       Impact factor: 11.136

6.  Reliability and validity assessment of a linear position transducer.

Authors:  Manuel V Garnacho-Castaño; Silvia López-Lastra; José L Maté-Muñoz
Journal:  J Sports Sci Med       Date:  2015-03-01       Impact factor: 2.988

7.  The Effects of Eccentric Cadence on Power and Velocity of the Bar during the Concentric Phase of the Bench Press Movement.

Authors:  Michal Wilk; Artur Golas; Michał Krzysztofik; Monika Nawrocka; Adam Zajac
Journal:  J Sports Sci Med       Date:  2019-06-01       Impact factor: 2.988

Review 8.  A brief review of strength and ballistic assessment methodologies in sport.

Authors:  Daniel Travis McMaster; Nicholas Gill; John Cronin; Michael McGuigan
Journal:  Sports Med       Date:  2014-05       Impact factor: 11.136

Review 9.  Towards a Determination of the Physiological Characteristics Distinguishing Successful Mixed Martial Arts Athletes: A Systematic Review of Combat Sport Literature.

Authors:  Lachlan P James; G Gregory Haff; Vincent G Kelly; Emma M Beckman
Journal:  Sports Med       Date:  2016-10       Impact factor: 11.136

Review 10.  Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review.

Authors:  Valentina Camomilla; Elena Bergamini; Silvia Fantozzi; Giuseppe Vannozzi
Journal:  Sensors (Basel)       Date:  2018-03-15       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.