Literature DB >> 17597694

Toxic anterior segment syndrome after cataract surgery--Maine, 2006.

.   

Abstract

Toxic anterior segment syndrome (TASS), an acute, noninfectious inflammation of the anterior segment of the eye, is a complication of anterior segment eye surgery; cataract extraction is the most common form of this type of surgery. Various contaminants, usually from surgical equipment or supplies, have been implicated as causes of TASS. The syndrome typically develops within 24 hours after surgery and is characterized by corneal edema and accumulation of white cells in the anterior chamber of the eye. Although most cases of TASS can be treated successfully with topical steroids, topical nonsteroidal antiinflammatory agents, or both, the inflammatory response associated with TASS can cause serious damage to intraocular tissues, resulting in vision loss. In October 2006, the Maine Department of Health and Human Services (MDHHS) received a report of a cluster of TASS cases among outpatients who had undergone cataract surgery at a hospital in Maine. MDHHS and CDC investigated the cluster and worked with the treating ophthalmologist and the hospital to prevent additional cases. This report describes the results of that investigation and the subsequent prevention measures implemented. Although the specific cause of the outbreak was not identified, no additional cases were reported after two series of changes were made to the materials and equipment used for surgery. Prevention of TASS requires careful attention to solutions, medications, and ophthalmic devices and to cleaning and sterilization of surgical equipment because of the numerous potential causes of the condition.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17597694

Source DB:  PubMed          Journal:  MMWR Morb Mortal Wkly Rep        ISSN: 0149-2195            Impact factor:   17.586


  3 in total

1.  The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery.

Authors:  Jason J Jones; Jeffrey Chu; Jacob Graham; Serge Zaluski; Guillermo Rocha
Journal:  Clin Ophthalmol       Date:  2016-06-17

2.  Injection time related to intraocular pressure using a CO2 driven preloaded injector: An experimental laboratory study.

Authors:  Jan N Weindler; Tadas Naujokaitis; Sonja K Schickhardt; Ramin Khoramnia; Gerd U Auffarth
Journal:  PLoS One       Date:  2021-07-19       Impact factor: 3.240

3.  Comparison of a new IOL injector system against 3 standard IOL injector systems with different incision sizes: Miyake-Apple view experimental laboratory study.

Authors:  Lu Zhang; Sonja Schickhardt; Hui Fang; Florian Auerbach; Perfecto Cagampang; Patrick R Merz; Gerd U Auffarth
Journal:  J Cataract Refract Surg       Date:  2022-02-01       Impact factor: 3.351

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.