Literature DB >> 17595212

Patient dose estimation for multi-detector-row CT examinations.

Kanae Nishizawa1, Shin-Ichiro Mori, Mari Ohno, Noriyuki Yanagawa, Takashi Yoshida, Keiichi Akahane, Kazuo Iwai, Shin-Ichi Wada.   

Abstract

The spread of Multi-detector-row computed tomography (MDCT) has been remarkable. Here, various organ and tissue doses were evaluated with six types of MDCT scanners in common use in Japan; using thermoluminescence dosimeters and anthropomorphic phantoms under condition of routine clinical examinations of the chest in adult and child, of the head in child and of the abdomen-pelvis in adult. Estimated lung doses and averaged effective dose in chest examinations were 19.2 +/- 2.03 mGy and 9.54 +/- 0.90 mSv for the adult and 15.7 +/- 1.88 mGy and 7.42 +/- 0.82 mSv for the child phantom, respectively. The numerical difference between effective dose and organ or tissue doses was about 2-2.5 times. For the adult abdomen-pelvis examinations, averaged effective dose was 13.0 +/- 3.72 mSv. Averaged effective dose for the child head examinations was 2.6 +/- 1.32 mSv. In one case, the dose approached 80 mGy for the brain in the head examination, giving a difference from the effective dose of 10 times or more.

Entities:  

Mesh:

Year:  2007        PMID: 17595212     DOI: 10.1093/rpd/ncm244

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  9 in total

1.  [Mechanical obstruction as a cause of acute abdomen. Radiological differential diagnosis].

Authors:  M Körner; U Linsenmaier; M Reiser
Journal:  Radiologe       Date:  2010-03       Impact factor: 0.635

2.  Radiation exposure from CT in early childhood: a French large-scale multicentre study.

Authors:  M-O Bernier; J-L Rehel; H J Brisse; X Wu-Zhou; S Caer-Lorho; S Jacob; J F Chateil; B Aubert; D Laurier
Journal:  Br J Radiol       Date:  2012-01       Impact factor: 3.039

3.  Radiation dose evaluation in 64-slice CT examinations with adult and paediatric anthropomorphic phantoms.

Authors:  K Fujii; T Aoyama; C Yamauchi-Kawaura; S Koyama; M Yamauchi; S Ko; K Akahane; K Nishizawa
Journal:  Br J Radiol       Date:  2009-12       Impact factor: 3.039

4.  Ultra-low-dose computed tomography system with a flat panel detector: assessment of radiation dose reduction and spatial and low contrast resolution.

Authors:  Yukihiro Nagatani; Norihisa Nitta; Masashi Takahashi; Noriaki Tezuka; Yasutaka Nakano; Mitsuru Ikeda; Yuki Kirino; Keiji Hashimoto; Hideji Otani; Yoko Murakami; Kiyoshi Murata
Journal:  Radiat Med       Date:  2009-01-08

5.  Radiation dose evaluation in head and neck MDCT examinations with a 6-year-old child anthropomorphic phantom.

Authors:  Chiyo Yamauchi-Kawaura; Keisuke Fujii; Takahiko Aoyama; Shuji Koyama; Masato Yamauchi
Journal:  Pediatr Radiol       Date:  2010-01-12

6.  A comparison of pediatric and adult CT organ dose estimation methods.

Authors:  Yiming Gao; Brian Quinn; Usman Mahmood; Daniel Long; Yusuf Erdi; Jean St Germain; Neeta Pandit-Taskar; X George Xu; Wesley E Bolch; Lawrence T Dauer
Journal:  BMC Med Imaging       Date:  2017-04-26       Impact factor: 1.930

7.  Patient-specific CT dosimetry calculation: a feasibility study.

Authors:  Thomas Fearon; Huchen Xie; Jason Y Cheng; Holly Ning; Ying Zhuge; Robert W Miller
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

8.  Tomotherapy as an Alternative Irradiative Treatment for Complicated Keloids.

Authors:  Yu-Fang Lin; Pei-Wei Shueng; Tyng-Luen Roan; Dun-Hao Chang; Yen-Chen Yu; Che-Wei Chang; An-Ta Kuo; Yo-Shen Chen; Hsiu-Wen Hsiao; Hui-Ju Tien; Chen-Hsi Hsieh
Journal:  J Clin Med       Date:  2020-11-20       Impact factor: 4.241

9.  Effective and organ doses using helical 4DCT for thoracic and abdominal therapies.

Authors:  Yuka Matsuzaki; Keisuke Fujii; Motoki Kumagai; Ichiro Tsuruoka; Shinichiro Mori
Journal:  J Radiat Res       Date:  2013-04-19       Impact factor: 2.724

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.