Literature DB >> 17591869

Effect of blinking on tear dynamics.

Jayachandra R Palakuru1, Jianhua Wang, James V Aquavella.   

Abstract

PURPOSE: Optical coherence tomography (OCT) was used to study the impact of blinking on tear dynamics.
METHODS: One eye of 21 subjects was imaged at the same time of day on two consecutive days. Dimensional information of the tear film and of the upper and lower tear menisci during normal and delayed blinking were obtained from OCT images using custom software. Digital camera images were used to measure eyelid length and ocular surface area for tear volume estimation.
RESULTS: No significant changes in any measured variable occurred between the two repeat visits. During normal and delayed blinking sessions, the tear film thickness increased significantly after each blink (P < 0.05) and then decreased (P < 0.05) during the open-eye period. For normal blinks, the tear meniscus did not change significantly during blinking or during the open-eye period. Except for upper tear meniscus curvature, all other parameters of tear menisci during delayed blinks were higher than those measured during normal blinks (P < 0.05). For delayed blinks, the lower tear meniscus height decreased after the blink (P < 0.05). Also for delayed blinks, the height and area of both upper and lower tear menisci significantly increased during the open-eye period. The total estimated tear volume on the ocular surface was greater during the delayed blinks (P < 0.01), and most of the volume was located in the lower tear meniscus (P < 0.01).
CONCLUSIONS: OCT is a promising tool for studying the impact of blinking on tear dynamics. Tear distribution is dynamically balanced and consistent during normal blinking, but it becomes altered during delayed blinking.

Entities:  

Mesh:

Year:  2007        PMID: 17591869     DOI: 10.1167/iovs.06-1507

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  31 in total

1.  Tear dysfunction and the cornea: LXVIII Edward Jackson Memorial Lecture.

Authors:  Stephen C Pflugfelder
Journal:  Am J Ophthalmol       Date:  2011-10-22       Impact factor: 5.258

Review 2.  The watery eye.

Authors:  Jianhua Wang; Meixiao Shen; Lele Cui; Michael R Wang
Journal:  Curr Allergy Asthma Rep       Date:  2011-06       Impact factor: 4.806

3.  A MODEL FOR THE TEAR FILM AND OCULAR SURFACE TEMPERATURE FOR PARTIAL BLINKS.

Authors:  Quan Deng; R J Braun; T A Driscoll; P E King-Smith
Journal:  Interfacial Phenom Heat Transf       Date:  2013

4.  Visualization of the precorneal tear film using ultrahigh resolution optical coherence tomography in dry eye.

Authors:  Lele Cui; Jianhua Wang; Victor L Perez; Meixiao Shen; Yimin Yuan; Michael R Wang
Journal:  Eye Contact Lens       Date:  2012-07       Impact factor: 2.018

5.  Neurostimulation of the lacrimal nerve for enhanced tear production.

Authors:  Andrea L Kossler; Jianhua Wang; William Feuer; David T Tse
Journal:  Ophthalmic Plast Reconstr Surg       Date:  2015 Mar-Apr       Impact factor: 1.746

6.  The effects of increasing ocular surface stimulation on blinking and sensation.

Authors:  Ziwei Wu; Carolyn G Begley; Ping Situ; Trefford Simpson
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-03-13       Impact factor: 4.799

7.  Spontaneous eyeblink activity under different conditions of gaze (eye position) and visual glare.

Authors:  Michael J Doughty
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-29       Impact factor: 3.117

8.  The effects of mild ocular surface stimulation and concentration on spontaneous blink parameters.

Authors:  Ziwei Wu; Carolyn G Begley; Ping Situ; Trefford Simpson; Haixia Liu
Journal:  Curr Eye Res       Date:  2013-09-18       Impact factor: 2.424

9.  Reproducibility of tear meniscus measurement by Fourier-domain optical coherence tomography: a pilot study.

Authors:  Sheng Zhou; Yan Li; Ake Tzu-Hui Lu; Pengfei Liu; Maolong Tang; Samuel C Yiu; David Huang
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2009 Sep-Oct

10.  Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system.

Authors:  Jing Dong; Qiang Wu; Xiao-Gang Wang
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779