Validation of a new arterial pulse contour-based cardiac output device.

Eric E C de Waal1, Cor J Kalkman, Steffen Rex, Wolfgang F Buhre.   

Abstract

OBJECTIVE: To evaluate the accuracy and precision of an arterial pulse contour-based continuous cardiac output device (Vigileo). Vigileo cardiac output (VigileoCO) was compared with intermittent transpulmonary thermodilution cardiac output (TPCO) and an established arterial pulse contour-based cardiac output (PCCO).
DESIGN: Prospective clinical study.
SETTING: University hospital. PATIENTS: Twenty-two patients undergoing coronary artery bypass graft surgery.
INTERVENTIONS: Defined volume load during surgery and in the postoperative period.
MEASUREMENTS AND MAIN RESULTS: We obtained 184 pairs of VigileoCO and TPCO, 140 pairs of VigileoCO and PCCO, and 140 pairs of PCCO and TPCO. Measurements were performed after induction of anesthesia (T1), after sternotomy (T2), immediately after (T3) and 20 mins after volume challenge with 10 mL.kg hydroxyethyl starch 6% (T4), 15 mins after coronary pulmonary bypass (T5), after retransfusion of autologous blood (T6), after arrival at the intensive care unit (T7), and immediately after (T8) and 20 mins after (T9) a second volume load with 10 mL.kg hydroxyethyl starch 6%. TPCO was used to calibrate PCCO. For pooled data, including uncalibrated PCCO data immediately after weaning from coronary pulmonary bypass (T5), the correlation coefficient of TPCO vs. VigileoCO, PCCO vs. VigileoCO, and TPCO vs. PCCO was 0.75, 0.60, and 0.75 respectively. Bland-Altman analysis showed a bias of 0.00, -0.01, and 0.02 L.min, the precision (=sd) was 0.87, 1.08, and 0.93 L.min, and the mean error was 33%, 40%, and 35%. When we compared calibrated PCCO values (T2-T4, T6, T7-9), the correlation coefficients of PCCO-VigileoCO and TPCO-PCCO were 0.72 and 0.85, bias was -0.16 and 0.19 L.min, and mean error was 33% and 27%, respectively. Best correlations and the least differences between TPCO and VigileoCO were observed in postbypass closed-chest conditions and in the intensive care unit.
CONCLUSIONS: Our results showed that VigileoCO enables clinically acceptable assessment of cardiac output in postbypass closed-chest conditions and during stable conditions in the intensive care unit.

Entities:  

Mesh:

Year:  2007        PMID: 17581493     DOI: 10.1097/01.CCM.0000275429.45312.8C

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  18 in total

Review 1.  Cardiac output monitoring devices: an analytic review.

Authors:  Jahan Porhomayon; Ali El-Solh; Peter Papadakos; Nader Djalal Nader
Journal:  Intern Emerg Med       Date:  2011-12-07       Impact factor: 3.397

Review 2.  Journal of Clinical Monitoring and Computing 2015 end of year summary: cardiovascular and hemodynamic monitoring.

Authors:  Karim Bendjelid; Steffen Rex; Thomas Scheeren; Bernd Saugel
Journal:  J Clin Monit Comput       Date:  2016-02-12       Impact factor: 2.502

Review 3.  Design, analysis, and interpretation of method-comparison studies.

Authors:  Sandra K Hanneman
Journal:  AACN Adv Crit Care       Date:  2008 Apr-Jun

4.  Pulse pressure: more than 100 years of changes in stroke volume.

Authors:  Maurizio Cecconi; Andrew Rhodes
Journal:  Intensive Care Med       Date:  2011-03-05       Impact factor: 17.440

5.  Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices.

Authors:  Pierre Squara; Maurizio Cecconi; Andrew Rhodes; Mervyn Singer; Jean-Daniel Chiche
Journal:  Intensive Care Med       Date:  2009-07-11       Impact factor: 17.440

6.  Continuous measurement of cardiac output using pulse-contour analysis: truly beat-to-beat?

Authors:  Steffen Rex
Journal:  J Clin Monit Comput       Date:  2014-11-15       Impact factor: 2.502

7.  Validation of continuous cardiac output technologies: consensus still awaited.

Authors:  Maurizio Cecconi; Andrew Rhodes
Journal:  Crit Care       Date:  2009-06-26       Impact factor: 9.097

8.  Arterial pressure-based cardiac output in septic patients: different accuracy of pulse contour and uncalibrated pressure waveform devices.

Authors:  Xavier Monnet; Nadia Anguel; Brice Naudin; Julien Jabot; Christian Richard; Jean-Louis Teboul
Journal:  Crit Care       Date:  2010-06-10       Impact factor: 9.097

9.  Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring.

Authors:  Sophie Marqué; Alain Cariou; Jean-Daniel Chiche; Pierre Squara
Journal:  Crit Care       Date:  2009-05-19       Impact factor: 9.097

10.  Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo/FloTrac device.

Authors:  Matthieu Biais; Lionel Vidil; Philippe Sarrabay; Vincent Cottenceau; Philippe Revel; François Sztark
Journal:  Crit Care       Date:  2009-12-07       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.