Literature DB >> 17580245

Thoracic aortic stent-graft devices: problems, failure modes, and applicability.

Christoph A Nienaber1, Stephan Kische, Hüseyin Ince.   

Abstract

Optimal treatment strategies for pathologies of the descending thoracic aorta are still controversial. Open surgery is complex, while endovascular devices allow nonsurgical access to the thoracic aorta. Endografts can be inserted via a peripheral artery while maintaining aortic blood flow without any need for clamping. Both short- and mid-term outcomes after endografting thoracic aneurysm and type B aortic dissection are encouraging, with significantly lower morbidity and early mortality compared with open surgery. However, despite emerging popularity and growing interest as an alternative to surgery, endograft design and manufacturing have not kept pace with growing clinical ambition. Major challenges associated with endovascular procedures using the current generation of endografts range from the relative rigidity and size of the delivery system to the failure of thoracic endografts to conform snugly to the anatomy of the aortic arch. Nonconformity of grafts may lead to graft instability, endoleak, and procedural failure. Current delivery systems are potentially traumatizing and, at times, too inflexible to track through tortuous, calcified vessels, and often require surgical exposure of the access vessel. Although efforts have been made by the industry to improve conformability and fixation in the aortic arch, given the spiraling movement of the thoracic aorta with each ventricular contraction, much work needs to be done on miniaturization and creation of disease-specific devices. The aim of this work is to give an overview on thoracic aortic stent-graft devices with focus on problems, failure modes and potential improvements.

Entities:  

Mesh:

Year:  2007        PMID: 17580245     DOI: 10.1053/j.semvascsurg.2007.04.005

Source DB:  PubMed          Journal:  Semin Vasc Surg        ISSN: 0895-7967            Impact factor:   1.000


  10 in total

1.  Assessment of thoracic aortic conformational changes by four-dimensional computed tomography angiography in patients with chronic aortic dissection type b.

Authors:  Tim F Weber; Maria-Katharina Ganten; Dittmar Böckler; Philipp Geisbüsch; Annette Kopp-Schneider; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Eur Radiol       Date:  2008-07-22       Impact factor: 5.315

2.  A computational study on the biomechanical factors related to stent-graft models in the thoracic aorta.

Authors:  S K Lam; George S K Fung; Stephen W K Cheng; K W Chow
Journal:  Med Biol Eng Comput       Date:  2008-07-11       Impact factor: 2.602

3.  Electromagnetic navigation for thoracic aortic stent-graft deployment: a pilot study in swine.

Authors:  Nadine Abi-Jaoudeh; Neil Glossop; Michael Dake; William F Pritchard; Alberto Chiesa; Matthew R Dreher; Thomas Tang; John W Karanian; Bradford J Wood
Journal:  J Vasc Interv Radiol       Date:  2010-04-09       Impact factor: 3.464

4.  Preprocedural planning for endovascular stent-graft placement.

Authors:  Gregory Kicska; Harold Litt
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

5.  Incomplete endograft apposition to the aortic arch: bird-beak configuration increases risk of endoleak formation after thoracic endovascular aortic repair.

Authors:  Takuya Ueda; Dominik Fleischmann; Michael D Dake; Geoffrey D Rubin; Daniel Y Sze
Journal:  Radiology       Date:  2010-05       Impact factor: 11.105

6.  Dynamic Changes in the Aorta During the Cardiac Cycle Analyzed by ECG-Gated Computed Tomography.

Authors:  Wenying Zhu; Yingliang Wang; Yang Chen; Jiacheng Liu; Chen Zhou; Qin Shi; Songjiang Huang; Chongtu Yang; Tongqiang Li; Bin Xiong
Journal:  Front Cardiovasc Med       Date:  2022-05-19

Review 7.  Acute Traumatic Thoracic Aortic Injury: Considerations and Reflections on the Endovascular Aneurysm Repair.

Authors:  Luca Di Marco; Davide Pacini; Roberto Di Bartolomeo
Journal:  Aorta (Stamford)       Date:  2013-07-01

8.  Standard of practice for the endovascular treatment of thoracic aortic aneurysms and type B dissections.

Authors:  Fabrizio Fanelli; Michael D Dake
Journal:  Cardiovasc Intervent Radiol       Date:  2009-08-18       Impact factor: 2.740

9.  Comparison of long-term clinical outcome between patients with chronic versus acute type B aortic dissection treated by implantation of a stent graft: a single-center report.

Authors:  Shao-Liang Chen; Jian-Cheng Zhu; Xiao-Bo Li; Fei Ye; Jun-Jie Zhang; Zhi-Zhong Liu; Nai-Liang Tian; Song Lin; Cheng-Yu Lv
Journal:  Patient Prefer Adherence       Date:  2013-04-22       Impact factor: 2.711

Review 10.  Interventional radiology in the elderly.

Authors:  Konstantinos Katsanos; Farhan Ahmad; Renato Dourado; Tarun Sabharwal; Andreas Adam
Journal:  Clin Interv Aging       Date:  2009-05-14       Impact factor: 4.458

  10 in total