Literature DB >> 17577355

Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release.

Burkhard Summer1, Ulrich Fink, Richard Zeller, Franziska Rueff, Sonja Maier, Gabriele Roider, Peter Thomas.   

Abstract

Nickel, chromium, and cobalt released from stainless steel and CoCrMo alloys have been postulated to trigger hypersensitivity reactions. The objective of this study was to assess the ion release from a CoCrMo alloy and stainless steel in vitro and the cutaneous reactivity to it by patch test. 52 metal-allergic patients and 48 non-allergic controls were patch tested to stainless steel and CoCrMo discs. In addition, using atomic absorption spectrometry, the release of nickel, cobalt, and chromium from both materials was assessed upon 2-day exposure to distilled water, artificial sweat (AS), and cell culture medium. There was low nickel ion release from stainless steel (0.3-0.46 microg/cm(2)/2 days) and CoCrMo discs (up to 0.33 microg/cm(2)/2 days) into the different elution media. Chromium release from the 2 materials was also very low (0.06-0.38 microg/cm(2)/2 days from stainless steel and 0.52-1.36 microg/cm(2)/2 days from CoCrMo alloy). In contrast, AS led to abundant cobalt release (maximally 18.94 microg/cm(2)/2 days) from the CoCrMo discs, with concomitant eczematous reaction upon patch testing: 0 of the 52 metal-allergic patients reacted to stainless steel discs and 5 of the 52 patients to CoCrMo discs (all 5 patients were cobalt allergic and 3 also nickel and chromium allergic). None of the controls reacted to the discs. Apart from nickel being a focus of allergological research, our results point to the possibly underestimated association of cobalt release and potential hyperreactivity to CoCrMo alloy.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17577355     DOI: 10.1111/j.1600-0536.2007.01139.x

Source DB:  PubMed          Journal:  Contact Dermatitis        ISSN: 0105-1873            Impact factor:   6.600


  7 in total

Review 1.  [Should metal alloy discs be used for patch testing in suspected metal implant intolerance reaction?].

Authors:  P Thomas; J Geier; H Dickel; T Diepgen; U Hillen; B Kreft; A Schnuch; C Szliska; V Mahler
Journal:  Orthopade       Date:  2015-11       Impact factor: 1.087

2.  [Preclinical evaluation of coated knee implants for allergic patients].

Authors:  J Reich; L Hovy; H-L Lindenmaier; R Zeller; J Schwiesau; P Thomas; T M Grupp
Journal:  Orthopade       Date:  2010-05       Impact factor: 1.087

3.  Metals and Metalloids Release from Orthodontic Elastomeric and Stainless Steel Ligatures: In Vitro Risk Assessment of Human Exposure.

Authors:  Aneta Olszewska; Anetta Hanć; Danuta Barałkiewicz; Piotr Rzymski
Journal:  Biol Trace Elem Res       Date:  2019-11-04       Impact factor: 3.738

4.  In vivo study on the release of nickel, chromium, and zinc in saliva and serum from patients treated with fixed orthodontic appliances.

Authors:  Dilip Daniel Quadras; U S Krishna Nayak; N Suchetha Kumari; H R Priyadarshini; Srinivasa Gowda; Bennete Fernandes
Journal:  Dent Res J (Isfahan)       Date:  2019 Jul-Aug

5.  Evaluation of Heat-Treated AISI 316 Stainless Steel in Solar Furnaces to Be Used as Possible Implant Material.

Authors:  Ioan Milosan; Monica Florescu; Daniel Cristea; Ionelia Voiculescu; Mihai Alin Pop; Inmaculada Cañadas; José Rodriguez; Cristina Aurica Bogatu; Tibor Bedo
Journal:  Materials (Basel)       Date:  2020-01-26       Impact factor: 3.623

Review 6.  Utility of Patch Testing and Lymphocyte Transformation Testing in the Evaluation of Metal Allergy in Patients with Orthopedic Implants.

Authors:  Logan J Richards; Alexandra Streifel; Jonathan M Rodrigues
Journal:  Cureus       Date:  2019-09-25

7.  DNA damage in oral mucosa cells of patients with fixed orthodontic appliances.

Authors:  Farzin Heravi; Mohammad Reza Abbaszadegan; Mohsen Merati; Nadia Hasanzadeh; Ezzat Dadkhah; Farzaneh Ahrari
Journal:  J Dent (Tehran)       Date:  2013-11-30
  7 in total