Literature DB >> 17572632

Evaluation of a new leg length measurement algorithm in hip arthroplasty.

Stephen B Murphy1, Timo M Ecker.   

Abstract

Leg length inequality after hip arthroplasty is a major source of patient dissatisfaction and dysfunction. Despite numerous reported methods to intraoperatively determine leg length change, it remains a challenge. We developed a reliable and reproducible method to measure leg length change using surgical navigation. The method measures the change in position of the femur relative to the pelvis and the pelvic coordinate system without the need to establish a femoral coordinate system. We replaced 112 hips in 107 patients using the new leg length measurement algorithm. Leg length change measured at surgery was compared with leg length change as measured on magnification-corrected pre- and postoperative radiographs. Compared with radiographically measured leg length change, the leg length changes measured intraoperatively had a mean difference of -0.5 +/- 1.77 mm (range, -5-3.9 mm). We found no difference between radiographic data and navigation data. Leg length change measured using surgical navigation, measuring the change in position of the femur relative to the pelvic coordinate system, without establishing a femoral coordinate system is easy and reliable.

Entities:  

Mesh:

Year:  2007        PMID: 17572632     DOI: 10.1097/BLO.0b013e318126c08f

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  10 in total

1.  Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study.

Authors:  Benjamin G Domb; Youssef F El Bitar; Adam Y Sadik; Christine E Stake; Itamar B Botser
Journal:  Clin Orthop Relat Res       Date:  2013-08-29       Impact factor: 4.176

2.  Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty.

Authors:  Geert Meermans; Ahmad Malik; Johan Witt; Fares Haddad
Journal:  Clin Orthop Relat Res       Date:  2010-09-29       Impact factor: 4.176

3.  Leg length discrepancy after total hip arthroplasty: a review of literature.

Authors:  Aravind S Desai; Asterios Dramis; Tim N Board
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

4.  Leg length and offset measures with a pinless femoral reference array during THA.

Authors:  Tobias Renkawitz; Tibor Schuster; Joachim Grifka; Thomas Kalteis; Ernst Sendtner
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

5.  Does robotic-assisted computer navigation improve acetabular cup positioning in total hip arthroplasty for Crowe III/IV hip dysplasia? A propensity score case-match analysis.

Authors:  Wei Chai; Chi Xu; Ren-Wen Guo; Pei-Fu Tang; Ji-Ying Chen; Xiang-Peng Kong; Jun Fu
Journal:  Int Orthop       Date:  2022-01-08       Impact factor: 3.075

Review 6.  Navigation in surgery.

Authors:  Uli Mezger; Claudia Jendrewski; Michael Bartels
Journal:  Langenbecks Arch Surg       Date:  2013-02-22       Impact factor: 3.445

7.  Total hip arthroplasty: leg length inequality impairs functional outcomes and patient satisfaction.

Authors:  Christoph Röder; Raphael Vogel; Lukas Burri; Daniel Dietrich; Lukas P Staub
Journal:  BMC Musculoskelet Disord       Date:  2012-06-11       Impact factor: 2.362

8.  Accurate leg length measurement in total hip arthroplasty: a comparison of computer navigation and a simple manual measurement device.

Authors:  Kyoichi Ogawa; Tamon Kabata; Toru Maeda; Yoshitomo Kajino; Hiroyuki Tsuchiya
Journal:  Clin Orthop Surg       Date:  2014-05-16

9.  Intraoperative measurement of limb lengthening during total hip arthroplasty.

Authors:  Dimitrios Vasileiou Papadopoulos; Panagiotis Koulouvaris; Georgios Charalambos Aggelidakis; Andreas Georgios Tsantes; Marios Georgios Lykissas; Alexandros Mavrodontidis
Journal:  Indian J Orthop       Date:  2017 Mar-Apr       Impact factor: 1.251

10.  Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study.

Authors:  Hiromasa Tanino; Yasuhiro Nishida; Ryo Mitsutake; Hiroshi Ito
Journal:  BMC Musculoskelet Disord       Date:  2021-03-23       Impact factor: 2.362

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.