Literature DB >> 17571693

Comparison of the uptake of polycyclic aromatic hydrocarbons and organochlorine pesticides by semipermeable membrane devices and caged fish (Carassius carassius) in Taihu Lake, China.

Runhui Ke1, Yiping Xu, Shengbiao Huang, Zijian Wang, James N Huckins.   

Abstract

Uptake of polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OCPs) by triolein-containing semipermeable membrane devices (SPMDs) and by crucian carp (Carassius carassius) was studied in Taihu Lake, a shallow, freshwater lake in China. Crucian carp and SPMDs were deployed side by side for 32 d. The first-order uptake rate constants of individual PAHs and OCPs for the two matrices were calculated and compared to relate the amounts of chemicals accumulated by the matrices to dissolved water concentrations. On a wet-weight basis, total concentrations of PAHs and OCPs in crucian carp fillets averaged 49.5 and 13.6 ng/g, respectively, after the 32-d exposure, whereas concentrations in whole SPMDs averaged 716.9 and 62.3 ng/g, respectively. The uptake rate constants of PAHs and OCPs by SPMDs averaged seven- and fivefold higher, respectively, than those for crucian carp; however, the patterns of uptake rate constants derived from test chemical concentrations in the crucian carp and SPMDs were similar. Although equilibrium was not reached for some PAHs and OCPs during the 32-d exposure period, a reasonably good correlation between the concentration factors (CFs) and octanol/water partition coefficient (Kow) values of PAHs and OCPs in SPMDs (r = 0.86, p < 0.001) was observed when potential sorption to dissolved organic carbon was taken into account. Similar efforts to correlate the CFs and Kow values of PAHs and OCPs in crucian carp (r = 0.75, p < 0.001) were less successful, likely because of PAH metabolism by finfish. Overall, the present results suggest that SPMDs may serve as a surrogate for contaminant monitoring with fish in freshwater lake environments.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17571693     DOI: 10.1897/06-454r1.1

Source DB:  PubMed          Journal:  Environ Toxicol Chem        ISSN: 0730-7268            Impact factor:   3.742


  6 in total

1.  Application of the triolein-embedded cellulose acetate membrane passive sampler for monitoring of polycyclic aromatic hydrocarbons in water.

Authors:  Jianfeng Tang; Guiying He; Gang Li
Journal:  Environ Sci Pollut Res Int       Date:  2014-05-27       Impact factor: 4.223

2.  Estimating risk at a Superfund site using passive sampling devices as biological surrogates in human health risk models.

Authors:  Sarah E Allan; Gregory J Sower; Kim A Anderson
Journal:  Chemosphere       Date:  2011-07-08       Impact factor: 7.086

3.  NMR-based metabolic profiling for serum of mouse exposed to source water.

Authors:  Yan Zhang; Weixin Li; Jie Sun; Rui Zhang; Bing Wu; Xuxiang Zhang; Shupei Cheng
Journal:  Ecotoxicology       Date:  2011-03-12       Impact factor: 2.823

4.  Adapting current model with field data of related performance reference compounds in passive samplers to accurately monitor hydrophobic organic compounds in aqueous media.

Authors:  Pokem Temoka; Gerd Pfister; Bernhard Henkelmann; Karl-Werner Schramm
Journal:  Environ Monit Assess       Date:  2017-10-07       Impact factor: 2.513

5.  Levels, distribution, and health risks of polycyclic aromatic hydrocarbons in four freshwater edible fish species from the Beijing market.

Authors:  Wen-Jing Wu; Ning Qin; Wei He; Qi-Shuang He; Hui-Ling Ouyang; Fu-Liu Xu
Journal:  ScientificWorldJournal       Date:  2012-12-31

6.  Predicting polycyclic aromatic hydrocarbon concentrations in resident aquatic organisms using passive samplers and partial least-squares calibration.

Authors:  Norman D Forsberg; Brian W Smith; Greg J Sower; Kim A Anderson
Journal:  Environ Sci Technol       Date:  2014-05-19       Impact factor: 9.028

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.