Literature DB >> 17571655

Cooling hyperthermic firefighters by immersing forearms and hands in 10 degrees C and 20 degrees C water.

Gordon G Giesbrecht1, Christopher Jamieson, Farrell Cahill.   

Abstract

INTRODUCTION: Firefighters experience significant heat stress while working with heavy gear in a hot, humid environment. This study compared the cooling effectiveness of immersing the forearms and hands in 10 and 20 degrees C water.
METHODS: Six men (33 +/- 10 yr; 180 +/- 4 cm; 78 +/- 9 kg; 19 +/- 5% body fat) wore firefighter 'turn-out gear' (heavy clothing and breathing apparatus weighing 27 kg) in a protocol including three 20-min exercise bouts (step test, 78 W, 40 degrees C air, 40% RH) each followed by a 20-min rest/cooling (21 degrees C air); i.e., 60 min of exercise, 60 min of cooling. Turn-out gear was removed during rest/cooling periods and subjects either rested (Control), immersed their hands in 10 or 20 degrees C water (H-10, H-20), or immersed their hands and forearms in 10 or 20 degrees C water (HF-10, HF-20).
RESULTS: In 20 degrees C water, hand immersion did not reduce core temperature compared with Control; however, including forearm immersion decreased core temperature below Control values after both the second and final exercise periods (p < 0.001). In 10 degrees C water, adding forearm with hand immersion produced a lower core temperature (0.8 degrees C above baseline) than all other conditions (1.1 to 1.4 degrees C above baseline) after the final exercise period (p < 0.001). Sweat loss during Control (1458 g) was greater than all active cooling protocols (1146 g) (p < 0.001), which were not different from each other. DISCUSSION: Hand and forearm immersion in cool water is simple, reduces heat strain, and may increase work performance in a hot, humid environment. With 20 degrees C water, forearms should be immersed with the hands to be effective. At lower water temperatures, forearm and/or hand immersion will be effective, although forearm immersion will decrease core temperature further.

Entities:  

Mesh:

Year:  2007        PMID: 17571655

Source DB:  PubMed          Journal:  Aviat Space Environ Med        ISSN: 0095-6562


  12 in total

1.  The impact of different cooling modalities on the physiological responses in firefighters during strenuous work performed in high environmental temperatures.

Authors:  David Barr; Thomas Reilly; Warren Gregson
Journal:  Eur J Appl Physiol       Date:  2010-11-16       Impact factor: 3.078

2.  Embracing the wild: conceptualizing wilderness medicine in Canada.

Authors:  Gwynn Curran-Sills; Neil McDonald; Paul S Auerbach; Rodney Crutcher
Journal:  Can Fam Physician       Date:  2013-05       Impact factor: 3.275

3.  Physiological and Perceived Effects of Forearm or Head Cooling During Simulated Firefighting Activity and Rehabilitation.

Authors:  Susan Yeargin; Amy L McKenzie; Lindsey E Eberman; J Derek Kingsley; David J Dziedzicki; Patrick Yoder
Journal:  J Athl Train       Date:  2016-11       Impact factor: 2.860

4.  A new mathematical model to simulate AVA cold-induced vasodilation reaction to local cooling.

Authors:  Mohamad Rida; Wafaa Karaki; Nesreen Ghaddar; Kamel Ghali; Jamal Hoballah
Journal:  Int J Biometeorol       Date:  2014-01-22       Impact factor: 3.787

5.  Comparison of active cooling devices with passive cooling for rehabilitation of firefighters performing exercise in thermal protective clothing: a report from the Fireground Rehab Evaluation (FIRE) trial.

Authors:  David Hostler; Steven E Reis; James C Bednez; Sarah Kerin; Joe Suyama
Journal:  Prehosp Emerg Care       Date:  2010 Jul-Sep       Impact factor: 3.077

6.  Body regional influences of L-menthol application on the alleviation of heat strain while wearing firefighter's protective clothing.

Authors:  Joo-Young Lee; Kouhei Nakao; Ilham Bakri; Yutaka Tochihara
Journal:  Eur J Appl Physiol       Date:  2011-10-02       Impact factor: 3.078

7.  A comparison of cooling techniques in firefighters after a live burn evolution.

Authors:  Deanna Colburn; Joe Suyama; Steven E Reis; Julia L Morley; Fredric L Goss; Yi-Fan Chen; Charity G Moore; David Hostler
Journal:  Prehosp Emerg Care       Date:  2011-02-04       Impact factor: 3.077

8.  Acute cardiovascular effects of firefighting and active cooling during rehabilitation.

Authors:  Jefferey L Burgess; Michael D Duncan; Chengcheng Hu; Sally R Littau; Delayne Caseman; Margaret Kurzius-Spencer; Grace Davis-Gorman; Paul F McDonagh
Journal:  J Occup Environ Med       Date:  2012-11       Impact factor: 2.162

9.  Effect of a cooling vest on core temperature in athletes with and without spinal cord injury.

Authors:  Michelle Trbovich; Catherine Ortega; James Schroeder; Mark Fredrickson
Journal:  Top Spinal Cord Inj Rehabil       Date:  2014

10.  Effect of wrist cooling on aerobic and anaerobic performance in elite sportsmen.

Authors:  Anup Krishnan; Krishan Singh; Deep Sharma; Vivekanand Upadhyay; Amit Singh
Journal:  Med J Armed Forces India       Date:  2017-05-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.