Undesirable nuclear reactions and induced radioactivity as a result of the use of the high-energy therapeutic beams generated by medical linacs.

Adam Konefal1, Kinga Polaczek-Grelik, Wiktor Zipper.   

Abstract

In this paper, the problem of undesirable photonuclear, electronuclear and neutron capture reactions taking place in the treatment room during emission of the typical high-energy therapeutic beams from two different medical accelerators, i.e. Primus Siemens and Varian Clinac-2300, is presented. The radioisotopes (187)W, (56)Mn, (28)Al, (57)Ni, (38)Cl, (57)Co and (19)Au and the neutron activation of (1)H were identified as a consequence of these reactions. Moreover, the increased photon fluence rate behind the door of the accelerator bunker in the operator console room was observed during emission of the 20 MV X-rays from the Varian Clinac-2300 as well as in the case of the 15 MV X-ray beam from the Primus Siemens. No increased radiation was observed during the 6 MV X-ray beam emission. The performed measurements produced evidences on the presence of neutrons in the operator console room during emission of the 15 MV X-ray beam from the Primus Siemens as well as the 20 MV X-rays and the 22 MeV electrons from the Varian Clinac-2300 accelerator.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17569692     DOI: 10.1093/rpd/ncm318

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  7 in total

1.  Secondary radiation dose during high-energy total body irradiation.

Authors:  M Janiszewska; K Polaczek-Grelik; M Raczkowski; B Szafron; A Konefał; W Zipper
Journal:  Strahlenther Onkol       Date:  2014-03-06       Impact factor: 3.621

2.  Thermal and resonance neutrons generated by various electron and X-ray therapeutic beams from medical linacs installed in polish oncological centers.

Authors:  Adam Konefał; Andrzej Orlef; Marcin Laciak; Aleksander Ciba; Marek Szewczuk
Journal:  Rep Pract Oncol Radiother       Date:  2012-07-12

3.  Cephalometric assessment of the axial inclination of upper and lower incisors in relation to the third-order angle.

Authors:  Michael Knösel; Rengin Attin; Dietmar Kubein-Meesenburg; Reza Sadat-Khonsari
Journal:  J Orofac Orthop       Date:  2007-05       Impact factor: 1.938

4.  MC safe bunker designing for an 18 MV linac with nanoparticles included primary barriers and effect of the nanoparticles on the shielding aspects.

Authors:  Amir Ghasemi-Jangjoo; Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2019-06-06

5.  Monte Carlo study on the secondary cancer risk estimations for patients undergoing prostate radiotherapy: A humanoid phantom study.

Authors:  Amir Ghasemi-Jangjoo; Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2020-01-10

6.  Application of the phase-space distribution approach of Monte Carlo for radiation contamination dose estimation from the (n,γ), (γ,n) nuclear reactions and linac leakage photons in the megavoltage radiotherapy facility.

Authors:  Amir Ghasemi-Jangjoo; Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2020-01-24

7.  Neutron and high energy photon fluence estimation in CLINAC using gold activation foils.

Authors:  Kh Haddad; O Anjak; B Yousef
Journal:  Rep Pract Oncol Radiother       Date:  2018-10-11
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.