Estimation of the wear volume after total hip replacement. A simple access to geometrical concepts.

T Ilchmann1, M Reimold, W Müller-Schauenburg.   

Abstract

Various formulas have been proposed to calculate the volume of prosthetic wear from the penetration depth of the head as assessed on plain radiographs, based on idealized, three-dimensional geometrical models of a prosthetic hip. However, for most published formulas no (or no simple) derivation is available and not all of them are correct. We describe a simple geometrical model that allows for transparent derivation of equations for various components of prosthetic wear volume and compare the calculated volumes with those obtained from published equations. These components are: (1) a right generalized cylinder resulting from a linear shift of a half spherical part of the prosthetic head into the hemispherical cup, (2) an additional wedge that is "cut" from the cup and (3) the wear from an optional additional cylindrical portion of the cup. We emphasize that calculation of a three-dimensional wear volume from linear penetration depth should be based on a geometrical concept that is transparent and simple enough for clinical research, such as the one presented. The incorrect formula of Kabo et al. should be completely abandoned.

Mesh:

Substances:

Year:  2007        PMID: 17569572     DOI: 10.1016/j.medengphy.2007.04.003

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  5 in total

1.  Wear analysis of chamfered elongated acetabular cup liners.

Authors:  Hsiao-Che Lin; Tzuo-Liang Luo; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2011-12-22       Impact factor: 2.602

2.  Wear patterns of, and wear volume formulae for, cylindrically elongated acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2010-04-28       Impact factor: 2.602

3.  Evaluating the accuracy of wear formulae for acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2009-10-10       Impact factor: 2.602

4.  Polyethylene wear is related to patient-specific contact stress in THA.

Authors:  Robert Košak; Veronika Kralj-Iglič; Aleš Iglič; Matej Daniel
Journal:  Clin Orthop Relat Res       Date:  2011-09-24       Impact factor: 4.176

5.  In vitro evaluation of stiffness graded artificial hip joint femur head in terms of joint stresses distributions and dimensions: finite element study.

Authors:  H Fouad
Journal:  J Mater Sci Mater Med       Date:  2011-04-20       Impact factor: 3.896

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.