Literature DB >> 17568544

A new method for output factor determination in MLC shaped narrow beams.

F Sánchez-Doblado1, G H Hartmann, J Pena, J V Roselló, G Russiello, D M Gonzalez-Castaño.   

Abstract

A new method for the measurement of output factors of narrow beams is presented in this work. By combining a new large area parallel plane ionization chamber (PTW model T34070) with a relative film dosimetry the output factors of small square fields of a 6 MV beam shaped by a MLC were measured. Several detectors (three ionization chambers, two solid state detectors and film) and Monte Carlo simulation were also employed to validate this new methodology and also to determine those detectors more suitable for narrow beam output factor determination. The proposed method for output factor measurement has shown to be in a very good agreement with diamond, diode and Monte Carlo results while it is insensitive to position displacements. Several uncertainties associated to the process of narrow beam dosimetry have also been addressed.

Entities:  

Mesh:

Year:  2007        PMID: 17568544     DOI: 10.1016/j.ejmp.2007.03.002

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  8 in total

Review 1.  Stereotactic radiosurgery alone for multiple brain metastases? A review of clinical and technical issues.

Authors:  Arjun Sahgal; Mark Ruschin; Lijun Ma; Wilko Verbakel; David Larson; Paul D Brown
Journal:  Neuro Oncol       Date:  2017-04-01       Impact factor: 12.300

2.  Beam commissioning of the first clinical biology-guided radiotherapy system.

Authors:  Bin Han; Dante Capaldi; Nataliya Kovalchuk; Eric Simiele; John White; Daniel Zaks; Lei Xing; Murat Surucu
Journal:  J Appl Clin Med Phys       Date:  2022-04-28       Impact factor: 2.243

3.  Survey of 5 mm small-field output factor measurements in Australia.

Authors:  Christopher P Oliver; Duncan J Butler; Viliami Takau; Ivan Williams
Journal:  J Appl Clin Med Phys       Date:  2018-01-25       Impact factor: 2.102

4.  Treatment planning system commissioning of the first clinical biology-guided radiotherapy machine.

Authors:  Eric Simiele; Dante Capaldi; Dylan Breitkreutz; Bin Han; Timothy Yeung; John White; Daniel Zaks; Michael Owens; Srinath Maganti; Lei Xing; Murat Surucu; Nataliya Kovalchuk
Journal:  J Appl Clin Med Phys       Date:  2022-05-29       Impact factor: 2.243

5.  Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters.

Authors:  Guerda Massillon-J L; Diego Cueva-Prócel; Porfirio Díaz-Aguirre; Miguel Rodríguez-Ponce; Flor Herrera-Martínez
Journal:  PLoS One       Date:  2013-05-09       Impact factor: 3.240

6.  Commissioning of a PTW 34070 large-area plane-parallel ionization chamber for small field megavoltage photon dosimetry.

Authors:  Tom Kupfer; Joerg Lehmann; Duncan J Butler; Ganesan Ramanathan; Tracy E Bailey; Rick D Franich
Journal:  J Appl Clin Med Phys       Date:  2017-10-04       Impact factor: 2.102

7.  The Radiological Physics Center's standard dataset for small field size output factors.

Authors:  David S Followill; Stephen F Kry; Lihong Qin; Jessica Lowenstein; Andrea Molineu; Paola Alvarez; Jose Francisco Aguirre; Geoffrey S Ibbott
Journal:  J Appl Clin Med Phys       Date:  2012-08-08       Impact factor: 2.102

8.  Experimental investigation of TRS-483 reference dosimetry correction factors for Leksell Gamma Knife® Icon™ beams.

Authors:  Wille Häger; Vaiva Kaveckyte; Hamza Benmakhlouf
Journal:  Med Phys       Date:  2020-11-21       Impact factor: 4.071

  8 in total