Literature DB >> 17567782

Is the volume of blood cultured still a significant factor in the diagnosis of bloodstream infections?

Emilio Bouza1, Dolores Sousa, Marta Rodríguez-Créixems, Juan García Lechuz, Patricia Muñoz.   

Abstract

"The higher the volume of blood cultured the higher the yield of blood cultures" has been a well-accepted dictum since J. A. Washington II performed his classic work. This rule has not been questioned in the era of highly automated blood culture machines, nor has it been correlated with clinical variables. Our objective in this study was to complete a prospective analysis of the relationship between blood volume, the yield of blood cultures, and the severity of clinical conditions in adult patients with suspected bloodstream infections (BSI). During a 6-month period, random samples of blood cultures were weighed to determine the volume of injected blood (weight/density). Overall, 298 patients with significant BSI and 303 patients with sepsis and negative blood cultures were studied. The mean volume of blood cultured in patients with BSI (30.03 +/- 14.96 ml [mean +/- standard deviation]) was lower than in patients without BSI (32.98 +/- 15.22 ml [P = 0.017]), and more episodes of bacteremia were detected with <20 ml (58.9%) than with >40 ml (40.2%) of blood cultured (P = 0.022). When patients were stratified according to the severity of their underlying condition, patients with BSI had higher APACHE II scores, and higher APACHE II scores were related to lower sample volumes (P < 0.001). A multivariate analysis showed that in the group of patients with APACHE II scores of >/=18, higher volumes yielded higher rates of bacteremia (odds ratio, 1.04 per ml of blood; 95% confidence interval, 1.001 to 1.08). We conclude that the higher yield of blood cultures inoculated with lower volumes of blood reflects the conditions of the population cultured. Washington's dictum holds true today in the era of automated blood culture machines.

Entities:  

Mesh:

Year:  2007        PMID: 17567782      PMCID: PMC2045273          DOI: 10.1128/JCM.00140-07

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  20 in total

Review 1.  Blood cultures: principles and techniques.

Authors:  J A Washington
Journal:  Mayo Clin Proc       Date:  1975-02       Impact factor: 7.616

2.  Effect of sample volume on yield of positive blood cultures from adult patients with haematological malignancy.

Authors:  D F Brown; R E Warren
Journal:  J Clin Pathol       Date:  1990-09       Impact factor: 3.411

3.  [Yield of blood cultures in relation to the cultured blood volume in Bactec 6A bottles].

Authors:  J Mensa; M Almela; C Casals; J A Martínez; F Marco; R Tomás; F Vidal; E Soriano; T Jiménez de Anta
Journal:  Med Clin (Barc)       Date:  1997-04-12       Impact factor: 1.725

4.  Nosocomial anemia.

Authors:  E Eyster; J Bernene
Journal:  JAMA       Date:  1973-01-01       Impact factor: 56.272

5.  A new method of classifying prognostic comorbidity in longitudinal studies: development and validation.

Authors:  M E Charlson; P Pompei; K L Ales; C R MacKenzie
Journal:  J Chronic Dis       Date:  1987

6.  Effects of volume and periodicity on blood cultures.

Authors:  J Li; J J Plorde; L G Carlson
Journal:  J Clin Microbiol       Date:  1994-11       Impact factor: 5.948

7.  Detection of bacteremia in adults: consequences of culturing an inadequate volume of blood.

Authors:  L A Mermel; D G Maki
Journal:  Ann Intern Med       Date:  1993-08-15       Impact factor: 25.391

8.  Clinical comparison of the resin-containing BACTEC 26 Plus and the Isolator 10 blood culturing systems.

Authors:  J J Tarrand; C Guillot; M Wenglar; J Jackson; J D Lajeunesse; K V Rolston
Journal:  J Clin Microbiol       Date:  1991-10       Impact factor: 5.948

9.  Blood culture technique based on centrifugation: clinical evaluation.

Authors:  G L Dorn; G G Burson; J R Haynes
Journal:  J Clin Microbiol       Date:  1976-03       Impact factor: 5.948

10.  Controlled evaluation of 5 versus 10 milliliters of blood cultured in aerobic BacT/Alert blood culture bottles.

Authors:  M P Weinstein; S Mirrett; M L Wilson; L G Reimer; L B Reller
Journal:  J Clin Microbiol       Date:  1994-09       Impact factor: 5.948

View more
  46 in total

1.  Optimized pathogen detection with 30- compared to 20-milliliter blood culture draws.

Authors:  Robin Patel; Emily A Vetter; W Scott Harmsen; Cathy D Schleck; Hind J Fadel; Franklin R Cockerill
Journal:  J Clin Microbiol       Date:  2011-10-05       Impact factor: 5.948

2.  Improved diagnosis of central venous catheter-related bloodstream infections using the HB&L UROQUATTRO™ system.

Authors:  C Fontana; M Favaro; M C Bossa; S Minelli; A Altieri; M Pelliccioni; F Falcione; L Di Traglia; O Cicchetti; C Favalli
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-06-27       Impact factor: 3.267

3.  Appropriateness of blood culture testing parameters in routine practice. Results from a cross-sectional study.

Authors:  V Vitrat-Hincky; P François; J Labarère; C Recule; J P Stahl; P Pavese
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2010-11-18       Impact factor: 3.267

Review 4.  Diagnosis of Bloodstream Infections in Children.

Authors:  Jennifer Dien Bard; Erin McElvania TeKippe
Journal:  J Clin Microbiol       Date:  2016-01-27       Impact factor: 5.948

5.  Assessing how many blood cultures are needed for detecting bloodstream infections.

Authors:  Federico G Nicola
Journal:  J Clin Microbiol       Date:  2008-03       Impact factor: 5.948

6.  Volume of blood cultured and APACHE II score: an intriguing diptych for diagnosis of bloodstream infections?

Authors:  Theodoros N Sergentanis; Anargiros Mariolis
Journal:  J Clin Microbiol       Date:  2008-08       Impact factor: 5.948

7.  Discrepant results from sampling different lumens of multilumen catheters: the case for sampling all lumens.

Authors:  J Cuellar-Rodriguez; D Connor; P Murray; J Gea-Banacloche
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-12-03       Impact factor: 3.267

8.  Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

Authors:  L Coorevits; A-M Van den Abeele
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-04-17       Impact factor: 3.267

9.  Contribution of the BacT/Alert MB Mycobacterium bottle to bloodstream infection surveillance in Thailand: added yield for Burkholderia pseudomallei.

Authors:  Possawat Jorakate; Melissa Higdon; Anek Kaewpan; Sirirat Makprasert; Somkhit Yuenprakhon; Kittisak Tawisaid; Surang Dejsirilert; Toni Whistler; Henry C Baggett
Journal:  J Clin Microbiol       Date:  2015-01-14       Impact factor: 5.948

Review 10.  A state of the art review on optimal practices to prevent, recognize, and manage complications associated with intravascular devices in the critically ill.

Authors:  Jean-François Timsit; Mark Rupp; Emilio Bouza; Vineet Chopra; Tarja Kärpänen; Kevin Laupland; Thiago Lisboa; Leonard Mermel; Olivier Mimoz; Jean-Jacques Parienti; Garyphalia Poulakou; Bertrand Souweine; Walter Zingg
Journal:  Intensive Care Med       Date:  2018-05-12       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.