Literature DB >> 17565512

Stabilization of an abutment under a rigidly fixed bridge by holographical-speckle interferometry.

Yan-Zhen Zhang1, Yan-Chun Zhou, Li Liu, Yang Lu, Yatani Hirofumi.   

Abstract

OBJECTIVE: There are no detailed reports of three-dimensional measurement of abutment teeth in mastication, because it is knotty to observe the rotation in chewing directly, and inexact to estimate indirectly. This work studies the three-dimensional stability of rigidly fixed bridge under the stresses of distributed loads and concentrated loads by optical method that gives the tip angle and rotation angle calculated directly based on measurement data.
METHODS: The specimen, taken from a 25-year-old male, was a left mandible without the second premolars and the first molars. As abutments, first premolar and second molar have complete periodontium. The specimen was soaked in formaldehyde solution. The bridge was fixed between two abutment teeth (first premolars and second molars), and the mandible was cemented in a steel box. The load was increased from 0 kg to 23 kg. Laser holographic technique was used to measure the three-dimensional bit shift of the dens, both buccolingual bit shift and mesiodistal bit shift, and determine tip angle and rotation angle.
RESULTS: The effects of stress distribution on the rigidly fixed bridge were evaluated, and stabilization of the bridge under the stresses of distributed loads and concentrated loads, respectively, were analyzed. The results showed that the tips of two abutments were very similar, and no distinct difference was observed between the distributed load and the concentrated load. However, the maximum rotation angle for the distributed load was two to four times as large as that for the concentrated load. In the experiment, the tip angle of the abutment teeth was no more than 0.65 degree, and the rotation angle was no more than 0.60 degree. All maximum angles occurred in the second molar.
CONCLUSION: The fixed bridge is considered to be safe. In addition, a method for measuring the rotation angle was provided effectively.

Entities:  

Mesh:

Year:  2007        PMID: 17565512      PMCID: PMC1879159          DOI: 10.1631/jzus.2007.B0416

Source DB:  PubMed          Journal:  J Zhejiang Univ Sci B        ISSN: 1673-1581            Impact factor:   3.066


  7 in total

1.  A novel method for the three-dimensional (3-D) analysis of orthodontic tooth movement-calculation of rotation about and translation along the finite helical axis.

Authors:  Kazuo Hayashi; Yoshima Araki; Jun Uechi; Hiroki Ohno; Itaru Mizoguchi
Journal:  J Biomech       Date:  2002-01       Impact factor: 2.712

Review 2.  The value of the centre of rotation in initial and longitudinal tooth and bone displacement.

Authors:  Guy De Pauw; Luc Dermaut; Hugo De Bruyn
Journal:  Eur J Orthod       Date:  2003-06       Impact factor: 3.075

3.  Laser holography in dentistry.

Authors:  J M Young; B R Altschuler
Journal:  J Prosthet Dent       Date:  1977-08       Impact factor: 3.426

4.  Finite element analysis of a mandibular model.

Authors:  J W Farah; R G Craig; K A Meroueh
Journal:  J Oral Rehabil       Date:  1988-11       Impact factor: 3.837

5.  Photoelastic analysis of internal stresses in the periodontium created by occlusal forces.

Authors:  I Glickman; F W Roeber; M Brion; J H Pameijer
Journal:  J Periodontol       Date:  1970-01       Impact factor: 6.993

6.  Measurement of strains in fixed bridges with electronic strain gauges.

Authors:  R G Craig; F A Peyton
Journal:  J Dent Res       Date:  1967 May-Jun       Impact factor: 6.116

7.  [FEM study on displacement, position of rotation center and stress distribution of PDL under various loading force systems].

Authors:  Dong-xu Liu; Chun-ling Wang; Chuan-yun Fu; Xiao-yan Zhang; Xiao-zhong Zheng
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2004-06
  7 in total
  1 in total

1.  Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading.

Authors:  Zhen-zhen Peng; Xin-min Chen; Jun Wang; Ai-jie Li; Zu-jie Xu
Journal:  J Zhejiang Univ Sci B       Date:  2013-06       Impact factor: 3.066

  1 in total