Literature DB >> 17561412

Coronary flow obstruction in percutaneous aortic valve replacement. An in vitro study.

Erwan M Flecher1, John W Curry, Thomas M Joudinaud, Corrine L Kegel, Patricia A Weber, Carlos M G Duran.   

Abstract

OBJECTIVE: Coronary flow obstruction is a serious complication reported in percutaneous aortic valve replacement. In an in vitro study of porcine hearts, the effects of valved stent implantation on coronary artery flow were studied with the native valve's leaflets intact and excised.
METHODS: The right and left main coronary arteries of porcine hearts were dissected 20mm distal to the aortic root and directed into lengths of latex tubing leading to collection flasks. The ascending aorta was cut proximal to the brachiocephalic trunk, cannulated, and attached to a constant-head water supply. After steady flow was achieved, the flow rate from each coronary artery was measured. In Group A (n=10), a tubular pericardial valve sutured into a cylindrical, cobalt-nickel stent was deployed orthotopically using a valvuloplasty balloon catheter. In Group B (n=10), the native leaflets were removed before similar valve deployment. Coronary flow measurements were repeated post-implantation.
RESULTS: In Group A, valve implantation resulted in a significant decrease in both left and right coronary flows. In Group B, no significant change in either right or left coronary flow was found after valve placement.
CONCLUSION: Implantation of a percutaneous valved stent in the orthotopic position with the native valve in place causes coronary ostial obstruction. This problem highlights the need for modified stents that are designed for implantation in patients with non-retracted, fibrotic, or calcified leaflets.

Entities:  

Mesh:

Year:  2007        PMID: 17561412     DOI: 10.1016/j.ejcts.2007.04.033

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  8 in total

1.  A novel device for endovascular native aortic valve resection for transapical transcatheter aortic valve implantation.

Authors:  Parla Astarci; David Glineur; Gébrine Elkhoury; Benoit Raucent
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-01-09

2.  Transcatheter aortic valve replacement: transapical resection of the aortic valve in vivo.

Authors:  René Bombien Quaden; Monika Leester-Schaedel; Lucian Lozonschi; Georg Lutter
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-06-15

3.  Modeling risk of coronary obstruction during transcatheter aortic valve replacement.

Authors:  Megan Heitkemper; Hoda Hatoum; Amirsepehr Azimian; Breandan Yeats; Jennifer Dollery; Bryan Whitson; Greg Rushing; Juan Crestanello; Scott M Lilly; Lakshmi Prasad Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2019-05-18       Impact factor: 5.209

4.  In vitro study of coronary flow occlusion in transcatheter aortic valve implantation.

Authors:  Zheng-Fu He; Wei-Ming Zhang; George Lutter; Rene Quaden; Jochen Cremer; Xiu-Jun Cai
Journal:  J Thorac Dis       Date:  2014-12       Impact factor: 2.895

5.  Emerging approaches of transcatheter valve repair/insertion.

Authors:  Maurizio Taramasso; Micaela Cioni; Andrea Giacomini; Iassen Michev; Cosmo Godino; Matteo Montorfano; Antonio Colombo; Ottavio Alfieri; Francesco Maisano
Journal:  Cardiol Res Pract       Date:  2010-07-25       Impact factor: 1.866

6.  Ex vivo and in vivo coronary ostial locations in humans.

Authors:  Joseph Knight; Vartan Kurtcuoglu; Karl Muffly; William Marshall; Paul Stolzmann; Lotus Desbiolles; Burkhardt Seifert; Dimos Poulikakos; Hatem Alkadhi
Journal:  Surg Radiol Anat       Date:  2009-03-14       Impact factor: 1.246

7.  Preliminary feasibility and hemodynamic performance of a newly-developed self-expanding bioprosthesis and 16-F delivery system in transcatheter aortic valve implantation in sheep.

Authors:  Jing Cai; Yanhui Sheng; Shijiang Zhang; Wei Sun; Rong Yang; Liping Miao; Xiangqing Kong
Journal:  J Biomed Res       Date:  2012-05-17

8.  A new type of aortic valved stent with good stability and no influence on coronary artery.

Authors:  Jianzhi Cai; Haitao Huang; Yongxin Zhou; Yunqing Mei; Jie Shao; Yongwu Wang
Journal:  J Cardiothorac Surg       Date:  2013-11-12       Impact factor: 1.637

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.