Literature DB >> 17558386

Plain X-ray and computed tomography of the orbit in cases and suspected cases of intraocular foreign body.

A Saeed1, L Cassidy, D E Malone, S Beatty.   

Abstract

AIM: To evaluate the roles of plain X-ray and computed tomography (CT) orbital imaging in cases and suspected cases of intraocular foreign body (IOFB).
METHODS: Retrospective review of clinical and radiological data relating to 204 consecutive cases and suspected cases of IOFB.SettingRoyal Victoria Eye and Ear Hospital, Dublin, Ireland.
RESULTS: Plain X-rays were performed in the absence of clinically evident ocular penetration in 177 (87%) cases, and no IOFB was demonstrated in any of these radiographs. Twenty-seven (13%) plain X-ray radiographs were obtained in the presence of clinically evident ocular penetration, and an IOFB was clinically visible in 19 (70%) of these cases. CT scans were undertaken in 21 (10%) of the 204 patients. Of these CT images, 9 (43%) and 12 (57%) were undertaken in the absence and presence of clinically evident ocular penetration, respectively. None (0%) and all (100%) of the CT scans obtained in the absence and presence of clinically evident ocular penetration demonstrated an IOFB, respectively.
CONCLUSION: Plain X-ray and CT orbital imaging are non-contributory in the absence of clinically evident ocular penetration. In the presence of clinically evident ocular penetration, and where an IOFB is clinically visible, plain X-ray orbital radiography may have a role in excluding multiple IOFBs. In the presence of clinically evident ocular penetration, but where an IOFB is not clinically visible, CT orbital imaging remains the investigation of choice, and the role of pre-CT plain X-ray orbital radiography, as recommended by the guidelines of the Royal College of Radiologists, merits re-evaluation.

Entities:  

Mesh:

Year:  2007        PMID: 17558386     DOI: 10.1038/sj.eye.6702876

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  5 in total

1.  [Accuracy and relevance of CT volumetry in open ocular injuries with intraocular foreign bodies].

Authors:  O A Maneschg; E Volek; Z Lohinai; M D Resch; A Papp; C Korom; K Karlinger; J Németh
Journal:  Ophthalmologe       Date:  2015-04       Impact factor: 1.059

2.  Clinical application of surface projection in the localization of metal foreign bodies using computed tomography scan.

Authors:  Hexiang Qian; Changwen Shi; Guangfu Xing
Journal:  Br J Radiol       Date:  2015-07-21       Impact factor: 3.039

3.  Intraocular Foreign Body: Diagnostic Protocols and Treatment Strategies in Ocular Trauma Patients.

Authors:  Hyun Chul Jung; Sang Yoon Lee; Chang Ki Yoon; Un Chul Park; Jang Won Heo; Eun Kyoung Lee
Journal:  J Clin Med       Date:  2021-04-25       Impact factor: 4.241

4.  Comparison of the efficacy and characteristics of metallic foreign body extraction by incision surgery and x-ray guided forceps after body-surface projection positioning: A STROBE-compliant article.

Authors:  Hexiang Qian; Xianju Qin; Guangfu Xing; Changwen Shi; Li Zhang
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

Review 5.  Open Globe Injuries: Review of Evaluation, Management, and Surgical Pearls.

Authors:  Yujia Zhou; Mark DiSclafani; Lauren Jeang; Ankit A Shah
Journal:  Clin Ophthalmol       Date:  2022-08-10
  5 in total