Literature DB >> 26194590

Clinical application of surface projection in the localization of metal foreign bodies using computed tomography scan.

Hexiang Qian1, Changwen Shi1, Guangfu Xing1.   

Abstract

OBJECTIVE: To analyse the clinical efficacy of surface projection in the localization and removal of metal foreign bodies using CT scan.
METHODS: Total 795 cases with 1008 metal foreign bodies were treated at our hospital in 2012. Pre-operative surface projection was performed to localize foreign bodies in patients under the guidance of CT scan. The removal path from the skin surface to foreign body and puncture site were then determined. Finally, the foreign bodies were extracted using proper foreign body forceps which were chosen according to the size, depth and position of the foreign bodies in different parts of the human body. The incision length, operative time and intraoperative blood loss were recorded. Additionally, outpatient follow-up was scheduled post-operatively for 1 week.
RESULTS: The accurate localization rate under the guidance of CT scan was 100%, and 1008 pieces of metal foreign bodies were all successfully removed with a removal rate of 100%. The mean incision length was 0.4 ± 0.1 cm, the mean operative time was 4.1 ± 2.0 min and the intraoperative blood loss was 1.1 ± 0.5 ml. These results showed minimal invasiveness, shorter operative time and minimal blood loss, respectively. Additionally, the results of outpatient follow-up showed that the wound healed spontaneously. Moreover, there were no significant bleeding, incision infections or complications.
CONCLUSION: Surface projection may be an accurate and effective method for the pre-operative localization and extraction of metal foreign bodies. ADVANCES IN KNOWLEDGE: (1) Surface projection was applied for localization of metal foreign bodies in our study. (2) The accurate localization rate of surface projection under the guidance of CT scan was 100%. (3) All foreign bodies were successfully removed with a removal rate of 100%. (4) Surface projection technique has advantages in the removal of foreign bodies.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26194590      PMCID: PMC4730963          DOI: 10.1259/bjr.20150075

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  29 in total

1.  Endoscopic removal of a long sharp metallic foreign body by a snared magnet: an attractive solution.

Authors:  Marcy Coash; George Y Wu
Journal:  J Dig Dis       Date:  2012-04       Impact factor: 2.325

2.  Image-guided removal of foreign bodies.

Authors:  G Eggers; C Haag; S Hassfeld
Journal:  Br J Oral Maxillofac Surg       Date:  2005-10       Impact factor: 1.651

3.  Comparison of the sensitivity for detecting foreign bodies among conventional plain radiography, computed tomography and ultrasonography.

Authors:  M H Aras; O Miloglu; C Barutcugil; M Kantarci; E Ozcan; A Harorli
Journal:  Dentomaxillofac Radiol       Date:  2010-02       Impact factor: 2.419

4.  Detection of soft-tissue foreign bodies by plain radiography, xerography, computed tomography, and ultrasonography.

Authors:  M J Ginsburg; G L Ellis; L L Flom
Journal:  Ann Emerg Med       Date:  1990-06       Impact factor: 5.721

5.  Detection and localization of steel intraocular foreign bodies using computed tomography. A comparison of helical and conventional axial scanning.

Authors:  J G Chacko; R E Figueroa; M H Johnson; D M Marcus; S E Brooks
Journal:  Ophthalmology       Date:  1997-02       Impact factor: 12.079

6.  Removal of a metallic foreign body in the neck with a magnet: A case report.

Authors:  John Mathai; Sadarudheen Ahmed; K P Pushpakumari; Anjana Mary Reynolds
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2007-12-11

7.  Perforation of the alimentary tract: evaluation with computed tomography.

Authors:  V Maniatis; H Chryssikopoulos; A Roussakis; C Kalamara; S Kavadias; A Papadopoulos; J Andreou; K Stringaris
Journal:  Abdom Imaging       Date:  2000 Jul-Aug

8.  Visual assessment versus quantitative three-dimensional stereotactic surface projection fluorodeoxyglucose positron emission tomography for detection of mild cognitive impairment and Alzheimer disease.

Authors:  Vance T Lehman; Rickey E Carter; Daniel O Claassen; Robert C Murphy; Val Lowe; Ronald C Petersen; Patrick J Peller
Journal:  Clin Nucl Med       Date:  2012-08       Impact factor: 7.794

9.  [Foreign body-induced angiosarcoma 60 years after a shell splinter injury].

Authors:  T Teltzrow; C Hallermann; S Müller; V Schwipper
Journal:  Mund Kiefer Gesichtschir       Date:  2006-11

10.  The use of a hand-held metal detector for localisation of ingested metallic foreign bodies - a critical investigation.

Authors:  Johannes Schalamon; Emir Q Haxhija; Herwig Ainoedhofer; Alja Gössler; Jürgen Schleef
Journal:  Eur J Pediatr       Date:  2004-02-05       Impact factor: 3.183

View more
  1 in total

1.  Comparison of the efficacy and characteristics of metallic foreign body extraction by incision surgery and x-ray guided forceps after body-surface projection positioning: A STROBE-compliant article.

Authors:  Hexiang Qian; Xianju Qin; Guangfu Xing; Changwen Shi; Li Zhang
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

  1 in total