| Literature DB >> 1755773 |
I R Whittle1, S W Denholm, K Elshunnar.
Abstract
Experience with a consecutive series of 125 computerized tomographic (CT) image guided stereotaxic neurosurgical procedures, performed using the Brown-Roberts-Wells (BRW) system is described. Operative objectives included tissue sampling for diagnostic purposes, intra-operative localization of craniotomy flaps and intracerebral lesions, cyst and abscess aspiration and lesion to modulate tremor. A neuropathological diagnosis was possible in 96% of the biopsies, and lesions were precisely localized in all patients undergoing microsurgical stereotaxic craniotomy. Two patients (2.2%) undergoing stereotaxic biopsy died as a result of the procedure and one patient's hemiparesis was permanently worsened (0.8%). In only one of three patients undergoing stereotaxic thalamotomy was tremor abolished. This report confirms that CT image guided stereotaxic neurosurgery is safe, accurate and versatile. There is, however, a moderate incidence (7.2%) of lesser complications that can occur with this type of surgery. These complications, which are emphasized in this paper, are related to both the site of surgery and the neuropathology.Entities:
Mesh:
Year: 1991 PMID: 1755773 DOI: 10.1111/j.1445-2197.1991.tb00010.x
Source DB: PubMed Journal: Aust N Z J Surg ISSN: 0004-8682