Literature DB >> 17557322

In vivo anterior tibial post contact after posterior stabilizing total knee arthroplasty.

George R Hanson1, Jeremy F Suggs, Young-Min Kwon, Andrew A Freiberg, Guoan Li.   

Abstract

Anterior polyethylene post failure in posterior stabilizing total knee arthroplasty (TKA) has been reported in recent patient follow-up studies. However, no data have been reported on the biomechanic interaction between the anterior tibial post and femoral component in posterior stabilizing TKA patients under physiological conditions. The objective of this study was to measure the in vivo anterior tibial post contact area at full knee extension using a dual-orthogonal fluoroscopic imaging technique. Eleven osteoarthritic patients were investigated after posterior stabilizing TKA to measure the contact between the femoral component box and anterior aspect of the tibial post. Anterior tibial post contact, ranging between 0.5 and 80.9 mm(2), was detected in 63% of the healthy patients (seven out of the eleven patients) at weight-bearing full extension of the knee. The patients with anterior tibial post contact had significantly higher hyperextension angles (-8.4 +/- 4.3 degrees) than those without contact (1.4 +/- 7.2 degrees). A statistically significant difference was also detected in the femoral component flexion with respect to the femoral shaft between the patients with anterior post contact (2.7 +/- 2.7 degrees) and without anterior post contact (-1.3 +/- 2.2 degrees). These data indicated that anterior post contact did occur in hyperextension within posterior stabilizing TKA patients. While excessive anterior tibial post contact may cause polyethylene wear and potentially lead to post failure, the tibial post may also act as a substitute for the ACL at low flexion, thus providing stability to the joint after posterior stabilizing TKA. (c) 2007 Orthopaedic Research Society.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17557322     DOI: 10.1002/jor.20417

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  8 in total

1.  Increased flexion position of the femoral component reduces the flexion gap in total knee arthroplasty.

Authors:  Georg Matziolis; Robert Hube; Carsten Perka; Doerte Matziolis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-22       Impact factor: 4.342

2.  The 2012 Mark Coventry award: a retrieval analysis of high flexion versus posterior-stabilized tibial inserts.

Authors:  Nicholas R Paterson; Matthew G Teeter; Steven J MacDonald; Richard W McCalden; Douglas D R Naudie
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

3.  Implant design influences tibial post wear damage in posterior-stabilized knees.

Authors:  Mark M Dolan; Natalie H Kelly; Joseph T Nguyen; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

4.  In vivo Kinematics of the Knee after a Posterior Cruciate-Substituting Total Knee Arthroplasty: A Comparison between Caucasian and South Korean Patients.

Authors:  Ji-Hoon Bae; Ali Hosseini; Kyung-Wook Nha; Sang-Eun Park; Tsung Yuan Tsai; Young-Min Kwon; Guoan Li
Journal:  Knee Surg Relat Res       Date:  2016-06-01

5.  Analysis of different bicruciate-retaining tibial prosthesis design using a three dimension finite element model.

Authors:  Peiheng He; Xing Li; Shuai Huang; Minghao Liu; Weizhi Chen; Dongliang Xu
Journal:  Am J Transl Res       Date:  2017-05-15       Impact factor: 4.060

6.  Knee kinematics in bi-cruciate stabilized total knee arthroplasty during squatting and stair-climbing activities.

Authors:  Koji Murakami; Satoshi Hamai; Ken Okazaki; Hirotaka Gondo; Yifeng Wang; Satoru Ikebe; Hidehiko Higaki; Takeshi Shimoto; Hideki Mizu-Uchi; Yukio Akasaki; Yasuharu Nakashima
Journal:  J Orthop       Date:  2018-05-07

7.  Comparison of stability and kinematics of the natural knee versus a PS TKA with a 'third condyle'.

Authors:  Stefano Zaffagnini; Simone Bignozzi; Mo Saffarini; Francesca Colle; Bharat Sharma; Plamen Slavov Kinov; Maurilio Marcacci; David Dejour
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-06       Impact factor: 4.342

8.  In vivo kinematics of gait in posterior-stabilized and bicruciate-stabilized total knee arthroplasties using image-matching techniques.

Authors:  Koji Murakami; Satoshi Hamai; Ken Okazaki; Yifeng Wang; Satoru Ikebe; Hidehiko Higaki; Takeshi Shimoto; Hideki Mizu-Uchi; Yukio Akasaki; Yasuharu Nakashima
Journal:  Int Orthop       Date:  2018-04-05       Impact factor: 3.075

  8 in total