Literature DB >> 17555245

Direct aperture optimization for online adaptive radiation therapy.

Ante Mestrovic1, Marie-Pierre Milette, Alan Nichol, Brenda G Clark, Karl Otto.   

Abstract

This paper is the first investigation of using direct aperture optimization (DAO) for online adaptive radiation therapy (ART). A geometrical model representing the anatomy of a typical prostate case was created. To simulate interfractional deformations, four different anatomical deformations were created by systematically deforming the original anatomy by various amounts (0.25, 0.50, 0.75, and 1.00 cm). We describe a series of techniques where the original treatment plan was adapted in order to correct for the deterioration of dose distribution quality caused by the anatomical deformations. We found that the average time needed to adapt the original plan to arrive at a clinically acceptable plan is roughly half of the time needed for a complete plan regeneration, for all four anatomical deformations. Furthermore, through modification of the DAO algorithm the optimization search space was reduced and the plan adaptation was significantly accelerated. For the first anatomical deformation (0.25 cm), the plan adaptation was six times more efficient than the complete plan regeneration. For the 0.50 and 0.75 cm deformations, the optimization efficiency was increased by a factor of roughly 3 compared to the complete plan regeneration. However, for the anatomical deformation of 1.00 cm, the reduction of the optimization search space during plan adaptation did not result in any efficiency improvement over the original (nonmodified) plan adaptation. The anatomical deformation of 1.00 cm demonstrates the limit of this approach. We propose an innovative approach to online ART in which the plan adaptation and radiation delivery are merged together and performed concurrently-adaptive radiation delivery (ARD). A fundamental advantage of ARD is the fact that radiation delivery can start almost immediately after image acquisition and evaluation. Most of the original plan adaptation is done during the radiation delivery, so the time spent adapting the original plan does not increase the overall time the patient has to spend on the treatment couch. As a consequence, the effective time allotted for plan adaptation is drastically reduced. For the 0.25, 0.5, and 0.75 cm anatomical deformations, the treatment time was increased by only 2, 4, and 6 s, respectively, as compared to no plan adaptation. For the anatomical deformation of 1.0 cm the time increase was substantially larger. The anatomical deformation of 1.0 cm represents an extreme case, which is rarely observed for the prostate, and again demonstrates the limit of this approach. ARD shows great potential for an online adaptive method with minimal extension of treatment time.

Entities:  

Mesh:

Year:  2007        PMID: 17555245     DOI: 10.1118/1.2719364

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Objective assessment of deformable image registration in radiotherapy: a multi-institution study.

Authors:  Rojano Kashani; Martina Hub; James M Balter; Marc L Kessler; Lei Dong; Lifei Zhang; Lei Xing; Yaoqin Xie; David Hawkes; Julia A Schnabel; Jamie McClelland; Sarang Joshi; Quan Chen; Weiguo Lu
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

2.  Search for IMRT inverse plans with piecewise constant fluence maps using compressed sensing techniques.

Authors:  Lei Zhu; Lei Xing
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

3.  Deterministic direct aperture optimization using multiphase piecewise constant segmentation.

Authors:  Dan Nguyen; Daniel O'Connor; Dan Ruan; Ke Sheng
Journal:  Med Phys       Date:  2017-09-22       Impact factor: 4.071

4.  Relationship of segment area and monitor unit efficiency in aperture-based IMRT optimization.

Authors:  Peng Qi; Ping Xia
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

5.  Dosimetric assessment of rigid setup error by CBCT for HN-IMRT.

Authors:  Danielle Worthy; Qiuwen Wu
Journal:  J Appl Clin Med Phys       Date:  2010-05-28       Impact factor: 2.102

6.  Accurate, robust and harmonized implementation of morpho-functional imaging in treatment planning for personalized radiotherapy.

Authors:  Elisa Jiménez-Ortega; Ana Ureba; José Antonio Baeza; Ana Rita Barbeiro; Marcin Balcerzyk; Ángel Parrado-Gallego; Amadeo Wals-Zurita; Francisco Javier García-Gómez; Antonio Leal
Journal:  PLoS One       Date:  2019-01-09       Impact factor: 3.240

7.  A Modular System for Treating Moving Anatomical Targets With Scanned Ion Beams at Multiple Facilities: Pre-Clinical Testing for Quality and Safety of Beam Delivery.

Authors:  Michelle Lis; Wayne Newhauser; Marco Donetti; Moritz Wolf; Timo Steinsberger; Athena Paz; Marco Durante; Christian Graeff
Journal:  Front Oncol       Date:  2021-03-19       Impact factor: 6.244

  7 in total