Literature DB >> 17554818

An optically powered single-channel stimulation implant as test system for chronic biocompatibility and biostability of miniaturized retinal vision prostheses.

Thomas Schanze1, Lutz Hesse, Carsten Lau, Nina Greve, Werner Haberer, Sascha Kammer, Thomas Doerge, Andreas Rentzos, Thomas Stieglitz.   

Abstract

A microsystem based microimplant with an optically powered single-channel stimulator was designed and developed as test system for an epi-retinal vision implant. Biostability of the hybrid assembly and the encapsulation materials were evaluated in pilot experiments in chronic implantations in a cat animal model. The implant was fabricated on a flexible polyimide substrate with integrated platinum electrode, interconnection lines, and contact pads for hybrid integration of electronic components. The receiver part was realized with four photodiodes connected in series. A parylene C coating was deposited on the electronic components as insulation layer. Silicone rubber was used to encapsulate the electronics in the shape of an artificial intraocular lens to allow proper implantation in the eye. Pilot experiments showed the biostability of the encapsulation approach and full electric functionality of the microimplant to generate stimulation currents over the implantation period of three months in two cats. In one cat, electrical stimulation of the retina evoked neuronal responses in the visual cortex and indicated the feasibility of the system approach for chronic use.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17554818     DOI: 10.1109/TBME.2007.895866

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

Review 1.  A review of in vivo animal studies in retinal prosthesis research.

Authors:  Dimiter R Bertschinger; Evgueny Beknazar; Manuel Simonutti; Avinoam B Safran; José A Sahel; Serge G Rosolen; Serge Picaud; Joel Salzmann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-08-16       Impact factor: 3.117

2.  Excimer laser deinsulation of Parylene-C on iridium for use in an activated iridium oxide film-coated Utah electrode array.

Authors:  Je-Min Yoo; Sandeep Negi; Prashant Tathireddy; Florian Solzbacher; Jong-In Song; Loren W Rieth
Journal:  J Neurosci Methods       Date:  2013-02-28       Impact factor: 2.390

3.  Toward a wide-field retinal prosthesis.

Authors:  Hossein Ameri; Tanapat Ratanapakorn; Stefan Ufer; Helmut Eckhardt; Mark S Humayun; James D Weiland
Journal:  J Neural Eng       Date:  2009-05-20       Impact factor: 5.379

4.  Biocompatibility of subretinal parylene-based Ti/Pt microelectrode array in rabbit for further artificial vision studies.

Authors:  Weihong Yu; Xuqian Wang; Chan Zhao; Zhikun Yang; Rongping Dai; Fangtian Dong
Journal:  J Ocul Biol Dis Infor       Date:  2009-03-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.