Evaluation of a new composite prosthesis for the repair of abdominal wall defects.

Paola Losi1, Antonella Munaò, Dario Spiller, Enrica Briganti, Ilaria Martinelli, Marco Scoccianti, Giorgio Soldani.   

Abstract

The degree of integration of biomaterials used in the repair of abdominal wall defects seems to depend upon the structure of the prosthesis. The present investigation evaluates the behaviour in terms of adhesion formation and integration of a new composite prosthesis that could be employed in this clinical application. Full-thickness abdominal wall defects (7 x 5 cm) were created in 16 anaesthetized New Zealand white rabbits and the prosthesis were placed in direct contact with the visceral peritoneum during the experiment. The defects were repaired with a composite prosthesis or pure polypropylene mesh to establish two study groups (n = 8 each). The composite device was constituted by a polypropylene mesh physically attached to a poly(ether)urethane-polydimethylsiloxane laminar sheet. Animals were sacrificed 7, 14, 21 and 30 days after implant and prosthesis/surrounding tissue specimens subjected to light and electron microscopy. Firm adhesions were detected in the polypropylene implants, while they were not present in the composite implants. The excellent behaviour of the composite prosthesis shown in this study warrants further investigation on its use for the repair of abdominal wall defects when a prosthetic device needs to be placed in contact with the intestinal loops.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17554600     DOI: 10.1007/s10856-007-3101-y

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  17 in total

1.  A comparison of suture repair with mesh repair for incisional hernia.

Authors:  R W Luijendijk; W C Hop; M P van den Tol; D C de Lange; M M Braaksma; J N IJzermans; R U Boelhouwer; B C de Vries; M K Salu; J C Wereldsma; C M Bruijninckx; J Jeekel
Journal:  N Engl J Med       Date:  2000-08-10       Impact factor: 91.245

2.  [Sterilization by the plasma procedure].

Authors:  J Pelletier
Journal:  Agressologie       Date:  1992

3.  The tension-free hernioplasty.

Authors:  I L Lichtenstein; A G Shulman; P K Amid; M M Montllor
Journal:  Am J Surg       Date:  1989-02       Impact factor: 2.565

4.  Colocutaneous fistula formation following polypropylene mesh placement for repair of a ventral hernia: diagnosis by colonoscopy.

Authors:  L J DeGuzman; L M Nyhus; G Yared; P K Schlesinger
Journal:  Endoscopy       Date:  1995-08       Impact factor: 10.093

5.  Neoperitoneal formation after implantation of various biomaterials for the repair of abdominal wall defects in rabbits.

Authors:  J M Bellón; L A Contreras; G Pascual; J Bujan
Journal:  Eur J Surg       Date:  1999-02

6.  Use of nonporous polytetrafluoroethylene prosthesis in combination with polypropylene prosthetic abdominal wall implants in prevention of peritoneal adhesions.

Authors:  J M Bellón; J Buján; L A Contreras; F Jurado
Journal:  J Biomed Mater Res       Date:  1997

7.  Intraperitoneal treatment of incisional and umbilical hernias using an innovative composite mesh: four-year results of a prospective multicenter clinical trial.

Authors:  J G Balique; S Benchetrit; J L Bouillot; J B Flament; C Gouillat; P Jarsaillon; M Lepère; G Mantion; J P Arnaud; E Magne; F Brunetti
Journal:  Hernia       Date:  2004-12-02       Impact factor: 4.739

8.  In vitro mesothelialization of prosthetic materials designed for the repair of abdominal wall defects.

Authors:  J M Bellón; N García-Honduvilla; R López; C Corrales; F Jurado; J Buján
Journal:  J Mater Sci Mater Med       Date:  2003-04       Impact factor: 3.896

9.  Double-layer prostheses for repair of abdominal wall defects in a rabbit model.

Authors:  A P Walker; J Henderson; R E Condon
Journal:  J Surg Res       Date:  1993-07       Impact factor: 2.192

10.  Macrophage response to experimental implantation of polypropylene prostheses.

Authors:  J M Bellón; J Bujan; L Contreras; A Hernando; F Jurado
Journal:  Eur Surg Res       Date:  1994       Impact factor: 1.745

View more
  2 in total

1.  Biologic augmentation of rotator cuff repair.

Authors:  Scott R Montgomery; Frank A Petrigliano; Seth C Gamradt
Journal:  Curr Rev Musculoskelet Med       Date:  2011-12

2.  In vitro evaluation of the PEtU-PDMS material immunocompatibility: the influence of surface topography and PDMS content.

Authors:  D Spiller; C Mirtelli; P Losi; E Briganti; S Sbrana; S Counoupas; S Kull; S Tonlorenzi; G Soldani
Journal:  J Mater Sci Mater Med       Date:  2009-12       Impact factor: 3.896

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.