Literature DB >> 15348460

In vitro mesothelialization of prosthetic materials designed for the repair of abdominal wall defects.

J M Bellón1, N García-Honduvilla, R López, C Corrales, F Jurado, J Buján.   

Abstract

The aim of this study was to evaluate the in vitro response of mesothelial cells (MC) in terms of their ability to cover different biomaterials. MC were harvested from human omentum. The MC from the first passage were seeded onto different biomaterials from 10 min to 24 h: PL-PU99 (polypropylene-polyurethane); DM (ePTFE); PL (polypropylene); and PL + Col (polypropylene-collagen). The prosthetic surface covered was examined by microscopy and quantified. PL-PU99: The MC were adhered to the biomaterial 10 min post-incubation. At 4 h, the 53.12+/-7.86% of the prosthesis were coated with polygonal cells. At 12 h, 96.32+/-11.32% of the biomaterial was coated. DM: between 30 min to 8 h, the MC cells form small, round colonies. At 12 h, polygonal and fusiform secretory cells were observed (68.94+/-5.78%). 93.54+/-11.49% of surface was coated after 24 h. PL: only isolated cells were observed on the prosthesis. PL + Col: MC form a monolayer over prosthetic surface after 18 h (90.21+/-9.76). We conclude: (a) MC formed a stable monolayer over all the biomaterials tested with the exception of the PL due to its porosity. (b) The PL-PU99 showed the greatest potential for in vitro mesothelialization compared to the PL-Col and DM prostheses.

Entities:  

Year:  2003        PMID: 15348460     DOI: 10.1023/a:1022936016618

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  12 in total

1.  Enterocutaneous fistula 14 years after prosthetic mesh repair of a ventral incisional hernia: a life-long risk?

Authors:  D K Chew; L H Choi; A M Rogers
Journal:  Surgery       Date:  2000-03       Impact factor: 3.982

2.  Small bowel obstruction resulting from mesh plug migration after open inguinal hernia repair.

Authors:  J A Chuback; R S Singh; C Sills; L S Dick
Journal:  Surgery       Date:  2000-04       Impact factor: 3.982

3.  Repeated macroscopic haematuria caused by intravesical migration of a preperitoneal prosthesis.

Authors:  D Savioz; C Ludwig; C Leissing; J F Bolle; L Bühler; P Morel
Journal:  Eur J Surg       Date:  1997-08

4.  Mesothelial versus endothelial cell seeding: evaluation of cell adherence to a fibroblastic matrix using 111In oxine.

Authors:  J M Bellón; N García-Honduvilla; C Escudero; M J Gimeno; L Contreras; J de Haro; J Buján
Journal:  Eur J Vasc Endovasc Surg       Date:  1997-02       Impact factor: 7.069

5.  Marlex mesh in repair of a diaphragmatic defect later eroding into the distal esophagus and stomach.

Authors:  R Schneider; J L Herrington; A M Granda
Journal:  Am Surg       Date:  1979-05       Impact factor: 0.688

6.  Coatings for vascular prostheses: mesothelial cells express specific markers for muscle cells and have biological activity similar to that of endothelial cells.

Authors:  A Hernando; N García-Honduvilla; J M Bellón; J Buján; J Navlet
Journal:  Eur J Vasc Surg       Date:  1994-09

7.  Isolation and culture of microvascular endothelium from human adipose tissue.

Authors:  P A Kern; A Knedler; R H Eckel
Journal:  J Clin Invest       Date:  1983-06       Impact factor: 14.808

8.  Fecal fistula: a late complication of Marlex mesh repair.

Authors:  Z Kaufman; M Engelberg; M Zager
Journal:  Dis Colon Rectum       Date:  1981-10       Impact factor: 4.585

9.  Neoperitoneal formation after implantation of various biomaterials for the repair of abdominal wall defects in rabbits.

Authors:  J M Bellón; L A Contreras; G Pascual; J Bujan
Journal:  Eur J Surg       Date:  1999-02

10.  Use of a fibroblastic matrix improves the results of mesothelial-cell seeding on vascular prostheses of polytetrafluoroethylene.

Authors:  J Buján; N García-Honduvilla; A Hernando; J M Bellón
Journal:  Histol Histopathol       Date:  1995-10       Impact factor: 2.303

View more
  10 in total

1.  Improved biomechanical resistance using an expanded polytetrafluoroethylene composite-structure prosthesis.

Authors:  Juan M Bellón; Marta Rodríguez; Natalia Serrano; Antonio Carrera San-Martín; Julia Buján
Journal:  World J Surg       Date:  2004-04-19       Impact factor: 3.352

2.  Composite prostheses for the repair of abdominal wall defects: effect of the structure of the adhesion barrier component.

Authors:  J M Bellón; N García-Honduvilla; N Serrano; M Rodríguez; G Pascual; J Buján
Journal:  Hernia       Date:  2005-08-17       Impact factor: 4.739

3.  Evaluation of a new composite prosthesis for the repair of abdominal wall defects.

Authors:  Paola Losi; Antonella Munaò; Dario Spiller; Enrica Briganti; Ilaria Martinelli; Marco Scoccianti; Giorgio Soldani
Journal:  J Mater Sci Mater Med       Date:  2007-06-07       Impact factor: 3.896

4.  Postimplantation host tissue response and biodegradation of biologic versus polymer meshes implanted in an intraperitoneal position.

Authors:  G Pascual; B Pérez-Köhler; M Rodríguez; S Sotomayor; Juan M Bellón
Journal:  Surg Endosc       Date:  2013-09-18       Impact factor: 4.584

5.  Coated meshes for hernia repair provide comparable intraperitoneal adhesion prevention.

Authors:  Marc H F Schreinemacher; Kevin W Y van Barneveld; Rieky E G Dikmans; Marion J J Gijbels; Jan-Willem M Greve; Nicole D Bouvy
Journal:  Surg Endosc       Date:  2013-06-08       Impact factor: 4.584

6.  Postimplant intraperitoneal behavior of collagen-based meshes followed by laparoscopy.

Authors:  Juan M Bellón; Marta Rodríguez; Verónica Gómez-Gil; Sandra Sotomayor; Julia Buján; Gemma Pascual
Journal:  Surg Endosc       Date:  2011-07-26       Impact factor: 4.584

7.  Behaviour at the peritoneal interface of next-generation prosthetic materials for hernia repair.

Authors:  Gemma Pascual; Selma Benito-Martínez; Marta Rodríguez; Bárbara Pérez-Köhler; Francisca García-Moreno; Juan M Bellón
Journal:  Surg Endosc       Date:  2021-01-28       Impact factor: 4.584

8.  Evaluation of synthetic reticular hybrid meshes designed for intraperitoneal abdominal wall repair: Preclinical and in vitro behavior.

Authors:  Verónica Gómez-Gil; Marta Rodríguez; Francisca García-Moreno Nisa; Bárbara Pérez-Köhler; Gemma Pascual
Journal:  PLoS One       Date:  2019-02-27       Impact factor: 3.240

Review 9.  Polymer Hernia Repair Materials: Adapting to Patient Needs and Surgical Techniques.

Authors:  Marta Rodríguez; Verónica Gómez-Gil; Bárbara Pérez-Köhler; Gemma Pascual; Juan Manuel Bellón
Journal:  Materials (Basel)       Date:  2021-05-24       Impact factor: 3.623

10.  Behaviour of a new composite mesh for the repair of full-thickness abdominal wall defects in a rabbit model.

Authors:  Gemma Pascual; Sandra Sotomayor; Marta Rodríguez; Yves Bayon; Juan M Bellón
Journal:  PLoS One       Date:  2013-11-13       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.