Literature DB >> 17549217

The effect of low force chiropractic adjustments on body surface electromagnetic field.

John Zhang1, Brian J Snyder, Lori Vernor.   

Abstract

OBJECTIVE: The purpose of this study was to investigate the body surface electromagnetic field (EMF) changes using a sensitive magnetometer before and after a specific Toftness chiropractic adjustment in asymptomatic human subjects.
METHOD: Forty-four subjects were randomly assigned into control (20 subjects) and experimental groups (24 subjects) in a pre and post-test design. The Triaxial Fluxgate Magnetometer FGM-5DTAA (Walker Scientific, Worcester, Massachusetts) with five digit display and resolution of 1 nanotesla (nT) was used for EMF detection. The EMF in the research room and on the adjustment table was monitored and recorded. The subjects' body surface (cervical, thoracic, lumbar and sacral areas) EMF was determined in the prone position before and after the chiropractic adjustment. A low force Toftness chiropractic adjustment was applied to the cervical, thoracic, lumbar and sacral areas as determined by the practitioner.
RESULTS: The EMF in the research room was recorded as 41611 nT at the Z axis (earth field), 13761 nT at the X axis and 7438 nT at the Y axis. The EMF on the adjusting table changed minimally during the 15 minute observation period. The EMF on the subjects' body surface decreased at 4 spinal locations after chiropractic adjustment. The EMF (mean +/- SD in nT) decreased significantly at the cervical region from 42449 +/- 907 to 41643 +/- 1165 (p < 0.01) and at the sacral regions from 43206 +/- 760 to 42713 +/- 552 (p < 0.01). The EMF at the lumbar and thoracic regions decreased but did not reach a statistically significant level. No significant changes of the body surface EMF were found in the control group.
CONCLUSION: A low force Toftness chiropractic adjustment in the cervical and sacral areas resulted in a significant reduction of the cervical and sacral surface EMF. No significant body surface EMF changes were observed in the lumbar and thoracic regions. The mechanisms of the EMF reduction after chiropractic adjustment are not known.

Entities:  

Year:  2004        PMID: 17549217      PMCID: PMC1840038     

Source DB:  PubMed          Journal:  J Can Chiropr Assoc        ISSN: 0008-3194


  11 in total

1.  Health and safety implications of exposure to electromagnetic fields in the frequency range 300 Hz to 10 MHz.

Authors:  E Litvak; K R Foster; M H Repacholi
Journal:  Bioelectromagnetics       Date:  2002-01       Impact factor: 2.010

2.  Effects of extremely low frequency electromagnetic fields on hematologic and immunologic parameters in welders.

Authors:  Suleyman Dasdag; Cemil Sert; Zulkuf Akdag; Sabri Batun
Journal:  Arch Med Res       Date:  2002 Jan-Feb       Impact factor: 2.235

3.  Contact-evoked changes in EMG activity during human grasp.

Authors:  D F Collins; B Knight; A Prochazka
Journal:  J Neurophysiol       Date:  1999-05       Impact factor: 2.714

4.  Risk of cognitive impairment in relation to elevated exposure to electromagnetic fields.

Authors:  Chung-Yi Li; Fung-Chang Sung; Shwu Chong Wu
Journal:  J Occup Environ Med       Date:  2002-01       Impact factor: 2.162

Review 5.  Anatomical and technical considerations in surface electromyography.

Authors:  M Ferdjallah; J J Wertsch
Journal:  Phys Med Rehabil Clin N Am       Date:  1998-11       Impact factor: 1.784

6.  Body-surface map models for early diagnosis of acute myocardial infarction.

Authors:  I B Menown; R S Patterson; G MacKenzie; A A Adgey
Journal:  J Electrocardiol       Date:  1998       Impact factor: 1.438

7.  Fundamental issues on electromagnetic fields (EMF).

Authors:  A Novini
Journal:  Acupunct Electrother Res       Date:  1993 Jan-Mar       Impact factor: 0.143

8.  Active sodium transport and the electrophysiology of rabbit colon.

Authors:  S G Schultz; R A Frizzell; H N Nellans
Journal:  J Membr Biol       Date:  1977-05-12       Impact factor: 1.843

9.  Interexaminer reliability of the electromagnetic radiation receiver for determining lumbar spinal joint dysfunction in subjects with low back pain.

Authors:  H A Gemmell; B H Jacobson; S W Edwards; B J Heng
Journal:  J Manipulative Physiol Ther       Date:  1990 Mar-Apr       Impact factor: 1.437

10.  Exercise testing with myocardial perfusion imaging in patients with normal baseline electrocardiograms: cost savings with a stepwise diagnostic strategy.

Authors:  J A Mattera; S A Arain; A J Sinusas; L Finta; F J Wackers
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

View more
  4 in total

1.  The effect of low force chiropractic adjustments on body surface electromagnetic field.

Authors:  Cameron McDermaid
Journal:  J Can Chiropr Assoc       Date:  2004-09

2.  The effect of low force chiropractic adjustments on body surface electromagnetic field.

Authors:  Cam McDermaid
Journal:  J Can Chiropr Assoc       Date:  2004-12

Review 3.  Cerebrospinal fluid stasis and its clinical significance.

Authors:  James M Whedon; Donald Glassey
Journal:  Altern Ther Health Med       Date:  2009 May-Jun       Impact factor: 1.305

4.  Toftness system of chiropractic adjusting on pain syndromes: a pilot study in a multicenter setting.

Authors:  Brian J Snyder; John Zhang
Journal:  J Chiropr Med       Date:  2007-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.