Pre-denitrification in biofilters is limited by the amount of easily degradable organic substrate, resulting in relatively high requirements for external carbon. The combination of pre-DN, N and post-DN filters is much more advisable for most municipal wastewaters, because the recycle rate can be reduced and external carbon can be saved. For minimum use of external carbon, 100-150% recycle rate should not be exceeded. Then, approximately 50-60% of the total NO3-N can be depleted in the pre-DN stage. On average, 10 g total (t) COD/g NO3-N were required in the pre-DN stage for denitrification in the pilot and full-scale plant and 0.4-0.5 kg NO3-N/(m(3)DN d) can be reached without external carbon. As only 40-70% of the COD load is eliminated in the pre-DN, the remaining COD load is removed in the nitrification stage. 1 kg COD/(m(3) d) suppresses nitrification rates by approximately 0.1 kg NH4-N/(m(3) d). For nitrification rates, > 0.5 kg NH4N/(m(3) d) at 12 degrees C not more than 2 kg COD/(m(3) d) may be eliminated in the nitrification.Entities:
Mesh:
Substances:
Year: 2007 PMID: 17546977 DOI: 10.2166/wst.2007.249
Source DB: PubMed Journal: Water Sci Technol ISSN: 0273-1223 Impact factor: 1.915