Towards an ideal blood analogue for Doppler ultrasound phantoms.

C P Oates1.   

Abstract

If a phantom is to produce Doppler spectral waveforms accurately matching those that would be obtained in vivo, it is necessary to use a fluid that behaves like blood in vivo, both acoustically and rheologically. The use of blood itself is undesirable and an analogue is required. Blood exhibits non-Newtonian behaviour as a result of aggregation of erythrocytes at low shear rates. This behaviour affects flow not only in sub-millimetre diameter vessels, but also in large scale structures. An alternative to blood is described that uses finely powdered nylon suspended in a mixture of glycerol and water. The nylon particles used have dimensions and density close to those of erythrocytes and they aggregate at low shear rates to give non-Newtonian behaviour. Viscosity may be varied over a wide range by the addition of liquid detergent. Consideration is given to the importance of haematocrit in modelling pulsatile and disturbed flows as it affects the haemodynamics of flow and the backscattered power of an ultrasound beam. This adaptable blood analogue is suitable for use in models of both large structures and fine vessels.

Entities:  

Mesh:

Year:  1991        PMID: 1754614     DOI: 10.1088/0031-9155/36/11/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Viscoelasticity of blood and viscoelastic blood analogues for use in polydymethylsiloxane in vitro models of the circulatory system.

Authors:  Laura Campo-Deaño; Roel P A Dullens; Dirk G A L Aarts; Fernando T Pinho; Mónica S N Oliveira
Journal:  Biomicrofluidics       Date:  2013-05-17       Impact factor: 2.800

2.  Easy Pulsatile Phantom for Teaching and Validation of Flow Measurements in Ultrasound.

Authors:  M B Rominger; E-M Müller-Stuler; M Pinto; A S Becker; K Martini; T Frauenfelder; V Klingmüller
Journal:  Ultrasound Int Open       Date:  2016-07-13

3.  An ideal blood mimicking fluid for doppler ultrasound phantoms.

Authors:  H Samavat; J A Evans
Journal:  J Med Phys       Date:  2006-10

Review 4.  A Review of Suspension-Scattered Particles Used in Blood-Mimicking Fluid for Doppler Ultrasound Imaging.

Authors:  Ammar A Oglat; Nursakinah Suardi; M Z Matjafri; Mohammad A Oqlat; Mostafa A Abdelrahman; Ahmad A Oqlat
Journal:  J Med Ultrasound       Date:  2018-05-07

5.  Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques.

Authors:  Marwan Alshipli; Mohannad Adel Sayah; Ammar A Oglat
Journal:  J Med Ultrasound       Date:  2020-04-23

Review 6.  Chemical Items Used for Preparing Tissue-Mimicking Material of Wall-Less Flow Phantom for Doppler Ultrasound Imaging.

Authors:  Ammar A Oglat; M Z Matjafri; Nursakinah Suardi; Mohammad A Oqlat; Mostafa A Abdelrahman; Ahmad A Oqlat; Omar F Farhat; Batool N Alkhateb; Raed Abdalrheem; Muntaser S Ahmad; Mohammed Y M Abujazar
Journal:  J Med Ultrasound       Date:  2018-05-07

7.  A New Scatter Particle and Mixture Fluid for Preparing Blood Mimicking Fluid for Wall-Less Flow Phantom.

Authors:  Ammar A Oglat; M Z Matjafri; Nursakinah Suardi; Mostafa A Abdelrahman; Mohammad A Oqlat; Ahmad A Oqlat
Journal:  J Med Ultrasound       Date:  2018-09-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.