Literature DB >> 17536901

Transport characteristics of expiratory droplets and droplet nuclei in indoor environments with different ventilation airflow patterns.

M P Wan1, C Y H Chao.   

Abstract

Expiratory droplets and droplet nuclei can be pathogen carriers for airborne diseases. Their transport characteristics were studied in detail in two idealized floor-supply-type ventilation flow patterns: Unidirectional-upward and single-side-floor, using a multiphase numerical model. The model was validated by running interferometric Mie imaging experiments using test droplets with nonvolatile content, which formed droplet nuclei, ultimately, in a class-100 clean-room chamber. By comparing the droplet dispersion and removal characteristics with data of two other ceiling-supply ventilation systems collected from a previous work, deviations from the perfectly mixed ventilation condition were found to exist in various cases to different extent. The unidirectional-upward system was found to be more efficient in removing the smallest droplet nuclei (formed from 1.5 mum droplets) by air extraction, but it became less effective for larger droplets and droplet nuclei. Instead, the single-side-floor system was shown to be more favorable in removing these large droplets and droplet nuclei. In the single-side-floor system, the lateral overall dispersion coefficients for the small droplets and nuclei (initial size </=45 mum) were about an order of magnitude higher than those in the unidirectional-upward system. It indicated that bulk lateral airflow transport in the single-side-floor system was much stronger than the lateral dispersion mechanism induced mainly by air turbulence in the unidirectional-upward system. The time required for the droplets and droplet nuclei to be transported to the exhaust vent or deposition surfaces for removal varied with different ventilation flow patterns. Possible underestimation of exposure level existed if the perfectly mixed condition was assumed. For example, the weak lateral dispersion in the unidirectional ventilation systems made expiratory droplets and droplet nuclei stay at close distance to the source leading to highly nonuniform spatial distributions. The distance between the source and susceptible patients became an additional concern in exposure analysis. Relative significance of the air-extraction removal mechanism was studied. This can have impact to the performance evaluation of filtration and disinfection systems installed in the indoor environment. These findings revealed the need for further development in a risk-assessment model incorporating the effect of different ventilation systems on distributing expiratory droplets and droplet nuclei nonuniformly in various indoor spaces, such as buildings, aircraft cabins, trains, etc.

Entities:  

Mesh:

Year:  2007        PMID: 17536901     DOI: 10.1115/1.2720911

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  13 in total

1.  Exhaled droplets due to talking and coughing.

Authors:  Xiaojian Xie; Yuguo Li; Hequan Sun; Li Liu
Journal:  J R Soc Interface       Date:  2009-10-07       Impact factor: 4.118

2.  An experimental study quantifying pulmonary ventilation on inhalation of aerosol under steady and episodic emission.

Authors:  Carmen K M Poon; Alvin C K Lai
Journal:  J Hazard Mater       Date:  2011-07-12       Impact factor: 10.588

Review 3.  Observing and quantifying airflows in the infection control of aerosol- and airborne-transmitted diseases: an overview of approaches.

Authors:  J W Tang; C J Noakes; P V Nielsen; I Eames; A Nicolle; Y Li; G S Settles
Journal:  J Hosp Infect       Date:  2010-12-30       Impact factor: 3.926

Review 4.  The role of particle size in aerosolised pathogen transmission: a review.

Authors:  Jan Gralton; Euan Tovey; Mary-Louise McLaws; William D Rawlinson
Journal:  J Infect       Date:  2010-11-19       Impact factor: 6.072

5.  Investigating the airborne transmission pathway - different approaches with the same objectives.

Authors:  Julian W Tang
Journal:  Indoor Air       Date:  2015-04       Impact factor: 5.770

6.  Experimental study on the control effect of different ventilation systems on fine particles in a simulated hospital ward.

Authors:  Xiangfei Kong; Chenli Guo; Zhang Lin; Shasha Duan; Junjie He; Yue Ren; Jianlin Ren
Journal:  Sustain Cities Soc       Date:  2021-06-17       Impact factor: 7.587

7.  Transient transport model of particles resulting from high momentum respiratory activities: Inter-personal exposure.

Authors:  Carine Habchi; Kamel Ghali; Nesreen Ghaddar
Journal:  Build Environ       Date:  2015-07-31       Impact factor: 6.456

8.  Directional Airflow and Ventilation in Hospitals: A Case Study of Secondary Airborne Infection.

Authors:  Ehsan S Mousavi; Kevin R Grosskopf
Journal:  Energy Procedia       Date:  2015-12-30

9.  Numerical modeling of exhaled droplet nuclei dispersion and mixing in indoor environments.

Authors:  K W Mui; L T Wong; C L Wu; Alvin C K Lai
Journal:  J Hazard Mater       Date:  2009-01-20       Impact factor: 10.588

10.  Role of air changes per hour (ACH) in possible transmission of airborne infections.

Authors:  Farhad Memarzadeh; Weiran Xu
Journal:  Build Simul       Date:  2011-12-22       Impact factor: 3.751

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.