Literature DB >> 17535622

Local anaesthetic infusion with elastomeric pump after arthroscopic subacromial decompression.

Kevin Little1, Anand Pillai, Umberto Fazzi, Neil Storey.   

Abstract

INTRODUCTION: The use of extended local anaesthesia for postoperative pain has previously been reported, and has several advantages over other methods, including ease of placement, safety, reliability, lower cost and effective analgesia. We present our experience with a portable elastomeric infusion device in patients undergoing arthroscopic subacromial decompression, and make a case for its potential to allow same-day discharge. PATIENTS AND METHODS: Forty patients undergoing arthroscopic subacromial decompression were followed-up. At the end of the procedure, an epidural catheter connected to a portable elastomeric local anaesthetic infusion system was inserted into the subacromial space. All patients were electively admitted for overnight stay postoperatively and assessed using a visual analogue scale (VAS) to evaluate their level of pain.
RESULTS: No patient reported severe pain at any stage. None of the patients required any parenteral opiate analgesia with the pump in situ.
CONCLUSIONS: These findings suggest that the use of this elastomeric infusion device following shoulder surgery allows safe and early discharge of patients with decreased need for parenteral opiate analgesia.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17535622      PMCID: PMC1963601          DOI: 10.1308/003588407X183300

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


  10 in total

Review 1.  Analgesia for day-case surgery.

Authors:  N Rawal
Journal:  Br J Anaesth       Date:  2001-07       Impact factor: 9.166

2.  Nerve injury associated with anesthesia: a closed claims analysis.

Authors:  F W Cheney; K B Domino; R A Caplan; K L Posner
Journal:  Anesthesiology       Date:  1999-04       Impact factor: 7.892

3.  Postoperative patient-controlled local anesthetic administration at home.

Authors:  N Rawal; K Axelsson; J Hylander; R Allvin; A Amilon; G Lidegran; J Hallén
Journal:  Anesth Analg       Date:  1998-01       Impact factor: 5.108

4.  The pain control infusion pump for postoperative pain control in shoulder surgery.

Authors:  F H Savoie; L D Field; R N Jenkins; W J Mallon; R A Phelps
Journal:  Arthroscopy       Date:  2000 May-Jun       Impact factor: 4.772

5.  Scalene regional anesthesia for shoulder surgery in a community setting: an assessment of risk.

Authors:  Stephen C Weber; Ritu Jain
Journal:  J Bone Joint Surg Am       Date:  2002-05       Impact factor: 5.284

6.  Interscalene regional anesthesia for shoulder surgery.

Authors:  Julie Y Bishop; Mark Sprague; Jonathan Gelber; Marina Krol; Meg A Rosenblatt; James Gladstone; Evan L Flatow
Journal:  J Bone Joint Surg Am       Date:  2005-05       Impact factor: 5.284

7.  Patient-controlled lidocaine analgesia for acromioplasty surgery.

Authors:  W J Mallon; C W Thomas
Journal:  J Shoulder Elbow Surg       Date:  2000 Mar-Apr       Impact factor: 3.019

8.  Wound perfusion with bupivacaine: objective evidence for efficacy in postoperative pain relief.

Authors:  J F Chester; K Ravindranath; B D White; D Shanahan; R S Taylor; K Lloyd-Williams
Journal:  Ann R Coll Surg Engl       Date:  1989-11       Impact factor: 1.891

9.  Analgesia for day-case shoulder surgery.

Authors:  A T Wilson; E Nicholson; L Burton; C Wild
Journal:  Br J Anaesth       Date:  2004-01-22       Impact factor: 9.166

10.  Delivery rate accuracy of portable, bolus-capable infusion pumps used for patient-controlled continuous regional analgesia.

Authors:  Brian M Ilfeld; Timothy E Morey; F Kayser Enneking
Journal:  Reg Anesth Pain Med       Date:  2003 Jan-Feb       Impact factor: 6.288

  10 in total
  2 in total

1.  Improving postoperative pain management in subpectoral tissue expander implant reconstruction of the breast using an elastomeric pump.

Authors:  A Chaudhry; S Hallam; A Chambers; A K Sahu; S Govindarajulu; S Cawthorn
Journal:  Ann R Coll Surg Engl       Date:  2015-07       Impact factor: 1.891

2.  Physicochemical stability of voriconazole in elastomeric devices.

Authors:  Harmanjeet Harmanjeet; Syed Tabish R Zaidi; Long Chiau Ming; Troy Wanandy; Rahul P Patel
Journal:  Eur J Hosp Pharm       Date:  2017-04-10