Thrombin formation in vitro in response to shear-induced activation of platelets.

Anna M Fallon1, Ulla M Marzec, Stephen R Hanson, Ajit P Yoganathan.   

Abstract

INTRODUCTION: Thromboembolic events caused by implanted vascular devices present serious medical challenges. In particular bileaflet mechanical heart valves (MHVs) are prone to thrombus formation in the hinge region due to a combination of high shear stress and stagnation regions. Most studies of shear-induced platelet activation and aggregation have been performed using viscometers, parallel plate flow, and other non-physiologic in vitro configurations. The present study investigated these events in a physiogically relevant environment in which thrombin formation in response to shear stress activation of platelets plays a more predominant role.
MATERIALS AND METHODS: Anticoagulated (citrated) human blood was placed in a steady flow loop containing a 400 microm round orifice or various MHVs in the leakage position. Simultaneous blood recalcification enhanced the thrombus forming potential of the blood. Aggrastat and AN51 were used to block binding to the platelet GPIIb/IIIa and GPIb receptors, respectively, and aspirin was used to block thromboxane production. Thrombin generation was measured indirectly by the thrombin-antithrombin III assay. RESULTS AND
CONCLUSIONS: Aggrastat, AN51, and aspirin all suppressed thrombin formation. Furthermore, histological results suggested important roles for vWF and fibrinogen in a two-step model of thrombus formation. Thus, thrombin is reproducibly formed in this in vitro system, a process that can be suppressed by blocking platelet activation. This system has the potential to investigate mechanisms and interventions for medical devices that contact with blood under varying shear stress conditions.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17532367     DOI: 10.1016/j.thromres.2007.04.006

Source DB:  PubMed          Journal:  Thromb Res        ISSN: 0049-3848            Impact factor:   3.944


  7 in total

1.  Numerical investigation of the effects of channel geometry on platelet activation and blood damage.

Authors:  Jingshu Wu; B Min Yun; Anna M Fallon; Stephen R Hanson; Cyrus K Aidun; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2010-10-26       Impact factor: 3.934

2.  Bileaflet mechanical heart valve closing sounds: in vitro classification by phonocardiographic analysis.

Authors:  Andrea Bagno; Federico Anzil; Roberto Buselli; Elena Pesavento; Vincenzo Tarzia; Vittorio Pengo; Tomaso Bottio; Gino Gerosa
Journal:  J Artif Organs       Date:  2009-09-19       Impact factor: 1.731

3.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

4.  Comparative classification of thrombotic formations on bileaflet mechanical heart valves by phonographic analysis.

Authors:  Clemens Romata; Francesca Maria Susin; Andrea Cambi; Vincenzo Tarzia; Vittorio Pengo; Gino Gerosa; Andrea Bagno
Journal:  J Artif Organs       Date:  2011-03-30       Impact factor: 1.731

5.  Quantification of particle residence time in abdominal aortic aneurysms using magnetic resonance imaging and computational fluid dynamics.

Authors:  Ga-Young Suh; Andrea S Les; Adam S Tenforde; Shawn C Shadden; Ryan L Spilker; Janice J Yeung; Christopher P Cheng; Robert J Herfkens; Ronald L Dalman; Charles A Taylor
Journal:  Ann Biomed Eng       Date:  2010-11-20       Impact factor: 3.934

Review 6.  Simulation of Mechanical Heart Valve Dysfunction and the Non-Newtonian Blood Model Approach.

Authors:  Aolin Chen; Adi Azriff Bin Basri; Norzian Bin Ismail; Masaaki Tamagawa; Di Zhu; Kamarul Arifin Ahmad
Journal:  Appl Bionics Biomech       Date:  2022-04-19       Impact factor: 1.664

Review 7.  Fluid mechanics of artificial heart valves.

Authors:  Lakshmi P Dasi; Helene A Simon; Philippe Sucosky; Ajit P Yoganathan
Journal:  Clin Exp Pharmacol Physiol       Date:  2009-02       Impact factor: 2.557

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.