Literature DB >> 17532218

Skin movement errors in measurement of sagittal lumbar and hip angles in young and elderly subjects.

Yi-Liang Kuo1, Elizabeth A Tully, Mary P Galea.   

Abstract

Errors in measurement of sagittal lumbar and hip angles due to skin movement on the pelvis and/or lateral thigh were measured in young (n = 21, age = 18.6 +/- 2.1 years) and older (n = 23, age = 70.9 +/- 6.4 years) age groups. Skin reference markers were attached over specific landmarks of healthy young and elderly subjects, who were videotaped in three static positions of hip flexion using the 2D PEAK Motus video analysis system. Sagittal lumbar and hip angles were calculated from skin reference markers and manually palpated landmarks. The elderly subjects demonstrated greater errors in lumbar angle due to skin movement on the pelvis only in the maximal hip flexion position. The traditional model (ASIS-PSIS-GT-LFE) underestimated sagittal hip angle and the revised model (ASIS-PSIS-2/3Th-1/4Th) provided more accurate measurement of sagittal hip angle throughout the full available range of hip flexion. Skin movement on the pelvis had a small counterbalancing effect on the larger errors from lateral thigh markers (GT-LFE), thereby decreasing hip angle error.

Entities:  

Mesh:

Year:  2007        PMID: 17532218     DOI: 10.1016/j.gaitpost.2007.03.016

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  6 in total

1.  Preliminary study: reliability of the spinal wheel. A novel device to measure spinal postures applied to sitting and standing.

Authors:  Liba Sheeran; Valerie Sparkes; Monica Busse; Robert van Deursen
Journal:  Eur Spine J       Date:  2009-12-15       Impact factor: 3.134

2.  In vivo relationship between pelvis motion and deep fascia displacement of the medial gastrocnemius: anatomical and functional implications.

Authors:  Carlos Cruz-Montecinos; Alberto González Blanche; David López Sánchez; Mauricio Cerda; Rodolfo Sanzana-Cuche; Antonio Cuesta-Vargas
Journal:  J Anat       Date:  2015-09-10       Impact factor: 2.610

3.  Acute effects of anterior thigh foam rolling on hip angle, knee angle, and rectus femoris length in the modified Thomas test.

Authors:  Andrew D Vigotsky; Gregory J Lehman; Bret Contreras; Chris Beardsley; Bryan Chung; Erin H Feser
Journal:  PeerJ       Date:  2015-09-24       Impact factor: 2.984

4.  Determination of thoracic and lumbar spinal processes by their percentage position between C7 and the PSIS level.

Authors:  Markus J Ernst; Fabian M Rast; Christoph M Bauer; Valentine L Marcar; Jan Kool
Journal:  BMC Res Notes       Date:  2013-02-11

5.  Joint torque variability and repeatability during cyclic flexion-extension of the elbow.

Authors:  Laurent Ballaz; Maxime Raison; Christine Detrembleur; Guillaume Gaudet; Martin Lemay
Journal:  BMC Sports Sci Med Rehabil       Date:  2016-04-11

6.  The modified Thomas test is not a valid measure of hip extension unless pelvic tilt is controlled.

Authors:  Andrew D Vigotsky; Gregory J Lehman; Chris Beardsley; Bret Contreras; Bryan Chung; Erin H Feser
Journal:  PeerJ       Date:  2016-08-11       Impact factor: 2.984

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.