PURPOSE: To evaluate the intraoperative performance and postoperative outcomes after microcoaxial phacoemulsification.
SETTING: Iladevi Cataract & IOL Research Centre, Ahmedabad, India.
METHODS: A prospective observational case series comprised 84 eyes with age-related uncomplicated cataract having microcoaxial phacoemulsification through a 2.2 mm clear corneal incision by a standard surgical technique. Phacoemulsification parameters (Infiniti Vision System, Alcon) were microburst width, 30 ms; preset power, 50%; vacuum, 650 mm Hg; aspiration flow rate, 25 cc/minute. A single-piece Alcon AcrySof intraocular lens was implanted with the C cartridge (Alcon) cartridge. The incision was measured at the end of surgery. Observations included surgical time (from commencement of sculpting to end of epinucleus removal), cumulative dissipated energy (CDE), wound burns, intraoperative complications, postoperative increase in mean central corneal thickness (CCT) at 1 day and 1 month, mean % decrease in endothelial cell density (ECD), absolute mean change in coefficient of variation (cv) 3 months, and uncorrected visual acuity (UCVA) at 1 day. Data were analyzed using a 1-sample t test with 95% confidence intervals (CIs).
RESULTS: The mean follow up was 3 months +/- 0.3 (SD). The mean incision size at the end of surgery was 2.3 +/- .09 mm; mean surgical time, 4.5 +/- 1.5 minutes; and mean CDE, 2.3 +/- 2.2 seconds. No wound burns or other intraoperative complications occurred. The postoperative CCT increased by a mean of 16 microm at 1 day (95% CI, 8-25; P = .66;) and by a mean of 3.14 microm at 1 month (95% CI, 2.26-4.05; P = .92). The ECD decreased by a mean of 5.8% (95% CI, 6.8-3.5; P = .82) and the mean coefficient of variation, by 3.3 (95% CI, 4.5-2.0; P = .65). At 1 day, the UCVA was 20/20 in 29% of cases, 20/20 to 20/40 in 58%, and 20/40 to 20/50 in 12%.
CONCLUSION: Microcoaxial phacoemulsification was safely and effectively performed, achieving consistent and satisfactory postoperative outcomes.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17531697     DOI: 10.1016/j.jcrs.2007.02.029

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Early clinical outcome with a new monofocal microincision intraocular lens.

Authors:  Baha Toygar; Ozge Yabas Kiziloglu; Okan Toygar; Ali Murat Hacimustafaoglu
Journal:  Int Ophthalmol       Date:  2016-01-16       Impact factor: 2.031

2.  Ozil® versus conventional ultrasound phacoemulsification: a randomized comparative study.

Authors:  Afef Maalej; Asma Khallouli; Cheima Wathek; Riadh Rannen
Journal:  Int Ophthalmol       Date:  2014-08-26       Impact factor: 2.031

3.  Clinical evaluation of surgery-induced astigmatism in cataract surgery using 2.2 mm or 1.8 mm clear corneal micro-incisions.

Authors:  Jun Yang; Xiu Wang; Hong Zhang; Yi Pang; Rui-Hua Wei
Journal:  Int J Ophthalmol       Date:  2017-01-18       Impact factor: 1.779

4.  Femtosecond laser-assisted cataract surgery with bimanual technique: learning curve for an experienced cataract surgeon.

Authors:  Gian Maria Cavallini; Tommaso Verdina; Michele De Maria; Elisa Fornasari; Elisa Volpini; Luca Campi
Journal:  Int Ophthalmol       Date:  2017-11-29       Impact factor: 2.031

5.  Corneal Optical Quality Following Sub 1.8 mm Micro-Incision Cataract Surgery vs. 2.2 mm Mini-Incision Coaxial Phacoemulsification.

Authors:  Jorge L Alió; Bassam Elkady; Dolores Ortiz
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

6.  Relationship between endothelial cell loss and microcoaxial phacoemulsification parameters in noncomplicated cataract surgery.

Authors:  Mohamed Ae Soliman Mahdy; Mohamed Z Eid; Mahmoud Abdel-Badei Mohammed; Amr Hafez; Jagdish Bhatia
Journal:  Clin Ophthalmol       Date:  2012-03-29

7.  Comparison of surgically-induced astigmatism after combined phacoemulsification and 23-gauge vitrectomy: 2.2-mm vs. 2.75-mm cataract surgery.

Authors:  Yong-Kyu Kim; Yong Woo Kim; Se Joon Woo; Kyu Hyung Park
Journal:  Korean J Ophthalmol       Date:  2014-03-14

8.  Long-term follow-up for bimanual microincision cataract surgery: comparison of results obtained by surgeons in training and experienced surgeons.

Authors:  Gian Maria Cavallini; Tommaso Verdina; Matteo Forlini; Veronica Volante; Michele De Maria; Giulio Torlai; Caterina Benatti; Giancarlo Delvecchio
Journal:  Clin Ophthalmol       Date:  2016-05-26

9.  Visual and refractive outcomes of new intraocular lens implantation after cataract surgery.

Authors:  Bhupesh Singh; Sourabh Sharma; Neha Bharti; Dharitri Samantrey; Dadan J Paandey; Sudhank Bharti
Journal:  Sci Rep       Date:  2022-08-18       Impact factor: 4.996

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.