Literature DB >> 17525767

A new strategy to replace the natural vitreous by a novel capsular artificial vitreous body with pressure-control valve.

Q Gao1, S Mou, J Ge, C-H To, Y Hui, A Liu, Z Wang, C Long, J Tan.   

Abstract

PURPOSE: The current vitreous substitutes such as silicone oil, heavy silicone oil, and polymeric gels that are directly injected into vitreous cavity frequently cause severe intraocular complications. There is a very urgent need to find a more suitable artificial vitreous substitute for pars plana vitrectomy (PPV) surgery.
METHODS: We have devised a novel capsular artificial vitreous using tailor-made silicone rubber elastomer. The novel device was implanted into the vitreous cavity of rabbit after PPV and the eye was examined by ophthalmoscopy, fundus photography, and tonometry during an 8-week treatment period. B-scan ultrasonography, electroretinogram (ERG), and histological studies by light microscopy were also performed at the end of 8 weeks.
RESULTS: The novel artificial vitreous body consists of a thin vitreous-like capsule with a silicone tube-valve system. The capsule can be folded and implanted into vitreous cavity through 1.5 mm incision on sclera. Physiological balanced solution (PBS) was then injected into the capsule and inflated to support retina and control intraocular pressure (IOP) through the tube-valve system subsequently fixed under the conjunctiva. Experiments using rabbits showed that the novel vitreous body could effectively support the retina and apparently induced no significant pathological changes in the eye over 8 weeks.
CONCLUSION: This approach may provide a new research strategy in the vitreous replacement technology. The novel artificial vitreous body device can effectively support retina, control IOP, and has good biocompatibility. It may be a good alternative to injecting artificial vitreous although its tamponade properties and usefulness still have to be proven in complex vitreoretinal diseases.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17525767     DOI: 10.1038/sj.eye.6702875

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  22 in total

1.  Evaluation of supporting role of a foldable capsular vitreous body with magnetic resonance imaging in the treatment of severe retinal detachment in human eyes.

Authors:  R Zhang; T Wang; C Xie; X Lin; Z Jiang; Z Wang; Y Liu; Y Luo; C Long; L He; P Wang; Q Gao
Journal:  Eye (Lond)       Date:  2011-03-18       Impact factor: 3.775

2.  Vitreous substitutes: challenges and directions.

Authors:  Qian-Ying Gao; Yue Fu; Yan-Nian Hui
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

3.  Experimental vitreous tamponade using polyalkylimide hydrogel.

Authors:  Sven Crafoord; Sten Andreasson; Fredrik Ghosh
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-03-31       Impact factor: 3.117

4.  Evaluation of viscoelastic poly(ethylene glycol) sols as vitreous substitutes in an experimental vitrectomy model in rabbits.

Authors:  Christopher D Pritchard; Sven Crafoord; Sten Andréasson; Karin M Arnér; Timothy M O'Shea; Robert Langer; Fredrik K Ghosh
Journal:  Acta Biomater       Date:  2010-11-24       Impact factor: 8.947

5.  Evaluation of the long-term effect of foldable capsular vitreous bodies in severe ocular rupture.

Authors:  Jin Deng; Hu-Ping Song; Rong-Le Zhou; Tao Chen; Jian-Zhou Wang; Zhao-Liang Zhu
Journal:  Int J Ophthalmol       Date:  2021-12-18       Impact factor: 1.779

6.  SILICONE OIL-FILLED FOLDABLE CAPSULAR VITREOUS BODY VERSUS SILICONE OIL ENDOTAMPONADE FOR TREATMENT OF NO LIGHT PERCEPTION AFTER SEVERE OCULAR TRAUMA.

Authors:  Chun Zhang; Ruihan Xiao; Anan Wang; Zhenquan Zhao
Journal:  Retina       Date:  2022-03-01       Impact factor: 3.975

7.  Protein kinase Cα downregulation via siRNA-PKCα released from foldable capsular vitreous body in cultured human retinal pigment epithelium cells.

Authors:  Xiaoqing Chen; Yaqin Liu; Zhaoxin Jiang; Lian Zhou; Jian Ge; Qianying Gao
Journal:  Int J Nanomedicine       Date:  2011-06-22

8.  Evaluation of the levofloxacin release characters from a rabbit foldable capsular vitreous body.

Authors:  Zhaoxin Jiang; Ting Wang; Biyan Pan; Zhiyong Xie; Peijuan Wang; Yaqin Liu; Qianying Gao
Journal:  Int J Nanomedicine       Date:  2011-12-30

9.  Comprehensive analysis of inflammatory immune mediators of the intraocular fluid aspirated from the foldable capsular vitreous body filled-eyes.

Authors:  Peijuan Wang; Qianying Gao; Xiaofeng Lin; Shaochong Zhang; Jie Hu; Yaqin Liu; Nuo Xu; Jian Ge
Journal:  PLoS One       Date:  2012-10-01       Impact factor: 3.240

10.  A novel vitreous substitute of using a foldable capsular vitreous body injected with polyvinylalcohol hydrogel.

Authors:  Songfu Feng; Han Chen; Yaqin Liu; Zhen Huang; Xuyuan Sun; Lian Zhou; Xiaohe Lu; Qianying Gao
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.