Literature DB >> 17521801

Attenuation and size distribution measurements of Definity and manipulated Definity populations.

David E Goertz1, Nico de Jong, Antonius F W van der Steen.   

Abstract

The contrast agent Definity has recently been shown to have substantial nonlinear activity at high ultrasound frequencies (>10 MHz). In this study, measurements were performed to characterize the frequency dependent attenuation properties of Definity and populations of Definity that had been modified to preferentially isolate smaller bubbles through decantation or mechanical filtration. A narrowband pulse-echo substitution method was employed with a series of four transducers covering the frequency range from 2 to 50 MHz. "Native" Definity has peak in attenuation in the vicinity of 10 MHz and remains high until 50 MHz. This pattern is significantly different from other clinically approved agents and is consistent with recent reports of nonlinear activity at high frequencies. With increasing decantation times, the attenuation peak becomes more diffuse and occurs at progressively higher frequencies. By 3 h for example, attenuation continues to rise until 30 MHz. The bubble size distribution undergoes preferential skewing toward smaller bubbles with increasing decantation time. Between 30 s and 3 h, the mean bubble diameter goes from 3.99 to 0.98 micrometers. Mechanical filtration with 2 and 1 microm pores causes attenuation to rise until 15 and 40 MHz, respectively. Definity can therefore be manipulated to improve its relative activity at higher frequencies (>10 MHz), which has implications for ultrasound biomicroscopy and intravascular ultrasound applications. Further, these results suggest that agent handling can have a substantial impact on size distributions affecting lower frequency applications. Shell friction estimates derived from these data are lower than those reported for larger bubbles at lower frequencies.

Mesh:

Substances:

Year:  2007        PMID: 17521801     DOI: 10.1016/j.ultrasmedbio.2007.03.009

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  60 in total

1.  Acoustic characterization of echogenic liposomes: frequency-dependent attenuation and backscatter.

Authors:  Jonathan A Kopechek; Kevin J Haworth; Jason L Raymond; T Douglas Mast; Stephen R Perrin; Melvin E Klegerman; Shaoling Huang; Tyrone M Porter; David D McPherson; Christy K Holland
Journal:  J Acoust Soc Am       Date:  2011-11       Impact factor: 1.840

Review 2.  Ultrasound enhanced drug delivery to the brain and central nervous system.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Int J Hyperthermia       Date:  2012       Impact factor: 3.914

3.  Individual lipid encapsulated microbubble radial oscillations: Effects of fluid viscosity.

Authors:  Brandon Helfield; Xucai Chen; Bin Qin; Flordeliza S Villanueva
Journal:  J Acoust Soc Am       Date:  2016-01       Impact factor: 1.840

Review 4.  In vitro methods to study bubble-cell interactions: Fundamentals and therapeutic applications.

Authors:  Guillaume Lajoinie; Ine De Cock; Constantin C Coussios; Ine Lentacker; Séverine Le Gac; Eleanor Stride; Michel Versluis
Journal:  Biomicrofluidics       Date:  2016-01-28       Impact factor: 2.800

Review 5.  Reverse engineering the ultrasound contrast agent.

Authors:  Mark A Borden; Kang-Ho Song
Journal:  Adv Colloid Interface Sci       Date:  2018-10-24       Impact factor: 12.984

6.  Theranostic Multilayer Capsules for Ultrasound Imaging and Guided Drug Delivery.

Authors:  Jun Chen; Sithira Ratnayaka; Aaron Alford; Veronika Kozlovskaya; Fei Liu; Bing Xue; Kenneth Hoyt; Eugenia Kharlampieva
Journal:  ACS Nano       Date:  2017-03-10       Impact factor: 15.881

7.  Modifying the size distribution of microbubble contrast agents for high-frequency subharmonic imaging.

Authors:  Himanshu Shekhar; Joshua J Rychak; Marvin M Doyley
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

Review 8.  Evaluating the safety profile of focused ultrasound and microbubble-mediated treatments to increase blood-brain barrier permeability.

Authors:  Dallan McMahon; Charissa Poon; Kullervo Hynynen
Journal:  Expert Opin Drug Deliv       Date:  2019-01-29       Impact factor: 6.648

Review 9.  Mechanisms of microbubble-facilitated sonoporation for drug and gene delivery.

Authors:  Zhenzhen Fan; Ronald E Kumon; Cheri X Deng
Journal:  Ther Deliv       Date:  2014-04

10.  On the relationship between microbubble fragmentation, deflation and broadband superharmonic signal production.

Authors:  Brooks D Lindsey; Juan D Rojas; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2015-03-09       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.