Literature DB >> 17512421

Fundamentals of intrathoracic impedance monitoring in heart failure.

Li Wang1.   

Abstract

The primary objective of the first-generation implantable cardiac pacemakers was to provide critical heart rate support, but these devices did not have any diagnostic capabilities. In the intervening decades, the number, type, and complexity of implantable devices has greatly expanded. Today, implantable devices not only provide heart rate support but they also provide protection from sudden cardiac death with implantable cardioverter defibrillators (ICDs) and reduce symptoms and increase survival with cardiac resynchronization therapy (CRT). Furthermore, information on physiologic variables has been collected in patients with implanted devices for the purpose of providing sophisticated closed-loop optimization of their pacing and defibrillation algorithms. Thoracic fluid status monitoring via intrathoracic impedance is the newest device-based diagnostic capability. For those patients with heart failure who are already targeted to receive an ICD or CRT with defibrillator implant, the ability to monitor fluid status can provide additional insight into the difficult problem of evaluating and managing these patients. This article reviews the basics of measuring intrathoracic impedance via OptiVol fluid status monitoring (Medtronic, Inc., Minneapolis, MN), as well as clinical results regarding the utility of evaluating OptiVol intrathoracic impedance data trends.

Entities:  

Mesh:

Year:  2007        PMID: 17512421     DOI: 10.1016/j.amjcard.2007.02.009

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  22 in total

1.  Increasing knowledge and changing views in cardiac resynchronization therapy.

Authors:  Laszlo Buga; John G F Cleland
Journal:  Heart Fail Rev       Date:  2012-11       Impact factor: 4.214

2.  Intrathoracic impedance monitoring detecting pneumonia.

Authors:  Christine Barth; I Kindermann; F Mahfoud; A Buob; M Böhm
Journal:  Clin Res Cardiol       Date:  2010-02-18       Impact factor: 5.460

Review 3.  Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems.

Authors:  Werner Jung; Andreas Rillig; Ralf Birkemeyer; Tomislav Miljak; Udo Meyerfeldt
Journal:  J Interv Card Electrophysiol       Date:  2008-09-27       Impact factor: 1.900

4.  Pulmonary fluid status monitoring with intrathoracic impedance.

Authors:  Nils Siegenthaler; Raphel Giraud; Karim Bendjelid
Journal:  J Clin Monit Comput       Date:  2011-01-12       Impact factor: 2.502

Review 5.  Internet-based device-assisted remote monitoring of cardiovascular implantable electronic devices: an evidence-based analysis.

Authors:  G Pron; L Ieraci; K Kaulback
Journal:  Ont Health Technol Assess Ser       Date:  2012-01-01

6.  Influence of lung volume, fluid and capillary recruitment during positional changes and exercise on thoracic impedance in heart failure.

Authors:  Chul-Ho Kim; Matthew A Fuglestad; Maile L Ceridon Richert; Win K Shen; Bruce D Johnson
Journal:  Respir Physiol Neurobiol       Date:  2014-08-14       Impact factor: 1.931

Review 7.  How to improve outcomes: should we put more emphasis on programming and medical care and less on patient selection?

Authors:  Laszlo Buga
Journal:  Heart Fail Rev       Date:  2012-11       Impact factor: 4.214

Review 8.  Self care in patients with chronic heart failure.

Authors:  Barbara Riegel; Christopher S Lee; Victoria Vaughan Dickson
Journal:  Nat Rev Cardiol       Date:  2011-07-19       Impact factor: 32.419

Review 9.  [Device-based remote monitoring : Current evidence].

Authors:  David Duncker; Roman Michalski; Johanna Müller-Leisse; Christos Zormpas; Thorben König; Christian Veltmann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2017-08-15

10.  Prediction of All-Cause Mortality Based on the Direct Measurement of Intrathoracic Impedance.

Authors:  Michael R Zile; Vinod Sharma; James W Johnson; Eduardo N Warman; Catalin F Baicu; Tom D Bennett
Journal:  Circ Heart Fail       Date:  2015-12-23       Impact factor: 8.790

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.