Literature DB >> 1750934

Contaminated patellar tendon grafts: incidence of positive cultures and efficacy of an antibiotic solution soak--an in vitro study.

D E Cooper1, S P Arnoczky, R F Warren.   

Abstract

The incidence of positive cultures after contamination of sterile patellar tendon grafts in an operating room environment was studied in 10 specimens. The grafts were dropped on the floor for 3 min and then cultured. Six of the 10 grafts (60%) had a positive culture at 10 days. To test the efficacy of an antibiotic solution on cleansing contaminated grafts, 10 additional grafts were dropped on the floor for 3 min. Before the grafts were cultured they were soaked in a sterile saline solution containing bacitracin (33.33 U/ml) and polymyxin B (333.33 U/ml) for 15 min. Thirty percent of these grafts (3 of 10) cultured positive at 10 days. In each case the bacterial contaminant was found to be sensitive to one of the antibiotic agents used in the cleansing solution. The results of this study suggest that although soaking contaminated grafts in this antibiotic solution for 15 min may reduce the incidence of positive cultures, it still results in a 30% incidence of nonsterile grafts.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1750934     DOI: 10.1016/0749-8063(91)90125-h

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  9 in total

1.  Evaluation of sterilization methods following contamination of hamstring autograft during anterior cruciate ligament reconstruction.

Authors:  Matthew J Plante; Xinning Li; Gail Scully; Michael A Brown; Brian D Busconi; Nicola A DeAngelis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-15       Impact factor: 4.342

2.  Intra-operative hamstring tendon graft contamination in anterior cruciate ligament reconstruction.

Authors:  Iosif Gavriilidis; Emilios E Pakos; Benjamin Wipfler; Ioannis S Benetos; Hans H Paessler
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-06-18       Impact factor: 4.342

3.  Remodeling of ACL allografts is inhibited by peracetic acid sterilization.

Authors:  Sven U Scheffler; Johannes Gonnermann; Julia Kamp; Dorothea Przybilla; Axel Pruss
Journal:  Clin Orthop Relat Res       Date:  2008-05-20       Impact factor: 4.176

4.  Hamstring graft bacterial contamination during anterior cruciate ligament reconstruction: clinical and microbiological study.

Authors:  Mohamad Aboelnour Badran; Dalia Mohamed Moemen
Journal:  Int Orthop       Date:  2016-03-29       Impact factor: 3.075

Review 5.  Comparison of the Sterilization Efficiency of 3 Disinfectants for Dropped Anterior Cruciate Ligament Grafts: A Systematic Review and Meta-analysis.

Authors:  Xianyue Shen; Yanguo Qin; Jianlin Zuo; Tong Liu; Jianlin Xiao
Journal:  Orthop J Sports Med       Date:  2021-05-10

6.  The Practices and Attitudes of Saudi Plastic Surgeons in Managing Contaminated Autologous Grafts.

Authors:  Fahad Aljindan; Fahad Alhumaid; Noor H Allababidi; Hatan Mortada; Salman Alzaidi
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-08-24

7.  Effect of three different sterilizing solutions on the contaminated bone: an experimental study in the rabbit.

Authors:  Hamidreza Yazdi; Mehdi Ramezan Shirazi; Omid Momen Shouli; Farzad Yazdi; Alireza Moslem
Journal:  Med J Islam Repub Iran       Date:  2012-08

8.  Contaminated osteochondral plugs: effect of different sterilizing solutions: an experimental study in the rabbit.

Authors:  Hamidreza Yazdi; Mehdi Ramezan Shirazi; Gholamreza Shafiee; Masoumeh Shahcheraghi
Journal:  Med J Islam Repub Iran       Date:  2012-11

9.  Management of contaminated autologous grafts in plastic surgery.

Authors:  Robert F Centeno; Ankit R Desai; Marla E Watson
Journal:  Eplasty       Date:  2008-04-22
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.