Literature DB >> 17503941

Four-channel magnetic resonance imaging receiver using frequency domain multiplexing.

Wang He1, Xu Qin, Ren Jiejing, Li Gengying.   

Abstract

An alternative technique that uses frequency domain multiplexing to acquire phased array magnetic resonance images is discussed in detail. The proposed method has advantages over traditional independent receiver chains in that it utilizes an analog-to-digital converter and a single-chip multicarrier receiver with high performance to reduce the size and cost of the phased array receiver system. A practical four-channel digital receiver using frequency domain multiplexing was implemented and verified on a home-built 0.3 T magnetic resonance imaging system. The experimental results confirmed that the cross talk between each channel was below -60 dB, the phase fluctuations were about 1 degrees , and there was no obvious signal-to-noise ratio degradation. It is demonstrated that the frequency domain multiplexing is a valuable and economical technique, particularly for array coil systems where the multichannel receiver is indispensable and dynamic range is not a critical problem.

Mesh:

Year:  2007        PMID: 17503941     DOI: 10.1063/1.2424426

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  5 in total

1.  Parallel magnetic resonance image reconstruction from a single-element parametric amplifier.

Authors:  Roshan Timilsina; Chunqi Qian
Journal:  Magn Reson Imaging       Date:  2019-08-16       Impact factor: 2.546

2.  Identification and mitigation of interference sources present in SSB-based wireless MRI receiver arrays.

Authors:  Matthew J Riffe; Michael D Twieg; Natalia Gudino; Colin J Blumenthal; Jeremiah A Heilman; Mark A Griswold
Journal:  Magn Reson Med       Date:  2013-02-14       Impact factor: 4.668

3.  MRI dynamic range and its compatibility with signal transmission media.

Authors:  Refaat E Gabr; Michael Schär; Arthur D Edelstein; Dara L Kraitchman; Paul A Bottomley; William A Edelstein
Journal:  J Magn Reson       Date:  2009-02-04       Impact factor: 2.229

4.  Wireless Reconfigurable RF Detector Array for Focal and Multiregional Signal Enhancement.

Authors:  Wei Qian; Xin Yu; Chunqi Qian
Journal:  IEEE Access       Date:  2020-07-24       Impact factor: 3.367

5.  Wireless Powered Encoding and Broadcasting of Frequency Modulated Detection Signals.

Authors:  Wei Qian; Xin Yu; Chunqi Qian
Journal:  IEEE Access       Date:  2020-11-04       Impact factor: 3.367

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.