Literature DB >> 17500461

Monte Carlo simulation of time-dependent, transport-limited fluorescent boundary measurements in frequency domain.

Tianshu Pan1, John C Rasmussen, Jae Hoon Lee, Eva M Sevick-Muraca.   

Abstract

Recently, we have presented and experimentally validated a unique numerical solver of the coupled radiative transfer equations (RTEs) for rapidly computing time-dependent excitation and fluorescent light propagation in small animal tomography. Herein, we present a time-dependent Monte Carlo algorithm to validate the forward RTE solver and investigate the impact of physical parameters upon transport-limited measurements in order to best direct the development of the RTE solver for optical tomography. Experimentally, the Monte Carlo simulations for both transport-limited and diffusion-limited propagations are validated using frequency domain photon migration measurements for 1.0%, 0.5%, and 0.2% intralipid solutions containing 1 microM indocyanine green in a 49 cm3 cylindrical phantom corresponding to the small volume employed in small animal tomography. The comparisons between Monte Carlo simulations and the numerical solutions result in mean percent error in amplitude and the phase shift less than 5.0% and 0.7 degrees, respectively, at excitation and emission wavelengths for varying anisotropic factors, lifetimes, and modulation frequencies. Monte Carlo simulations indicate that the accuracy of the forward model is enhanced using (i) suitable source models of photon delivery, (ii) accurate anisotropic factors, and (iii) accurate acceptance angles of collected photons. Monte Carlo simulations also show that the accuracy of the diffusion approximation in the small phantom depends upon (i) the ratio d(phantom)/l(tr), where d(phantom) is the phantom diameter and l(tr) is the transport mean free path; and (ii) the anisotropic factor of the medium. The Monte Carlo simulations validates and guides the future development of an appropriate RTE solver for deployment in small animal optical tomography.

Entities:  

Mesh:

Year:  2007        PMID: 17500461     DOI: 10.1118/1.2710549

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Comparison of Monte Carlo methods for fluorescence molecular tomography-computational efficiency.

Authors:  Jin Chen; Xavier Intes
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Radiative transport-based frequency-domain fluorescence tomography.

Authors:  Amit Joshi; John C Rasmussen; Eva M Sevick-Muraca; Todd A Wareing; John McGhee
Journal:  Phys Med Biol       Date:  2008-03-26       Impact factor: 3.609

3.  A parallel adaptive finite element simplified spherical harmonics approximation solver for frequency domain fluorescence molecular imaging.

Authors:  Yujie Lu; Banghe Zhu; Haiou Shen; John C Rasmussen; Ge Wang; Eva M Sevick-Muraca
Journal:  Phys Med Biol       Date:  2010-07-30       Impact factor: 3.609

4.  The vitamin B12 analog cobinamide is an effective hydrogen sulfide antidote in a lethal rabbit model.

Authors:  M Brenner; S Benavides; S B Mahon; J Lee; D Yoon; D Mukai; M Viseroi; A Chan; J Jiang; N Narula; S M Azer; C Alexander; G R Boss
Journal:  Clin Toxicol (Phila)       Date:  2014-04-09       Impact factor: 4.467

5.  Sulfanegen sodium treatment in a rabbit model of sub-lethal cyanide toxicity.

Authors:  Matthew Brenner; Jae G Kim; Jangwoen Lee; Sari B Mahon; Daniel Lemor; Rebecca Ahdout; Gerry R Boss; William Blackledge; Lauren Jann; Herbert T Nagasawa; Steven E Patterson
Journal:  Toxicol Appl Pharmacol       Date:  2010-08-10       Impact factor: 4.219

6.  High-resolution reconstruction of fluorescent inclusions in mouse thorax using anatomically guided sampling and parallel Monte Carlo computing.

Authors:  Xiaofeng Zhang; Cristian Badea; Greg Hood; Arthur Wetzel; Yi Qi; Joel Stiles; G Allan Johnson
Journal:  Biomed Opt Express       Date:  2011-07-29       Impact factor: 3.732

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.