On the discrepancies between Monte Carlo dose calculations and measurements for the 18 MV varian photon beam.

Omar Chibani1, C M Charlie Ma.   

Abstract

Significant discrepancies between Monte Carlo dose calculations and measurements for the Varian 18 MV photon beam with a large field size (40 x 40 cm2) were reported by different investigators. In this work, we investigated these discrepancies based on a new geometry model ("New Model") of the Varian 21EX linac using the GEPTS Monte Carlo code. Some geometric parameters used in previous investigations (Old Model) were inaccurate, as suggested by Chibani in his AAPM presentation (2004) and later confirmed by the manufacturer. The entrance and exit radii of the primary collimator of the New Model are 2 mm larger than previously thought. In addition to the corrected dimensions of the primary collimator, the New Model includes approximate models for the lead shield and the mirror frame between the monitor chamber and the Y jaws. A detailed analysis of the phase space data shows the effects of these corrections on the beam characteristics. The individual contributions from the linac component to the photon and electron fluences are calculated. The main source of discrepancy between measurements and calculations based on the Old Model is the underestimated electron contamination. The photon and electron fluences at the isocenter are 5.3% and 36% larger in the New Model in comparison with the Old Model. The flattening filter and the lead shield (plus the mirror frame) contribute 48.7% and 13% of the total electron contamination at the isocenter, respectively. For both open and filtered (2 mm Pb) fields, the calculated (New Model) and measured dose distributions are within 1% for depths larger than 1 cm. To solve the residual problem of large differences at shallow depths (8% at 0.25 cm depth), the detailed geometry of an IC-10 ionization chamber was simulated and the dose in the air cavity was calculated for different positions on the central axis including at the surface, where half of the chamber is outside the phantom. The calculated and measured chamber responses are within 3% even at the zero depth.

Entities:  

Mesh:

Year:  2007        PMID: 17500452     DOI: 10.1118/1.2712414

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Dose discrepancies in the buildup region and their impact on dose calculations for IMRT fields.

Authors:  Shu-Hui Hsu; Jean M Moran; Yu Chen; Ravi Kulasekere; Peter L Roberson
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

2.  Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams.

Authors:  D L Sawkey; B A Faddegon
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

3.  Simulation of large x-ray fields using independently measured source and geometry details.

Authors:  D Sawkey; B A Faddegon
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

4.  Determination of radiotherapy X-ray spectra using a screen-film system.

Authors:  H M Garnica-Garza
Journal:  Med Biol Eng Comput       Date:  2008-09-09       Impact factor: 2.602

5.  Monte Carlo Simulation of Siemens ONCOR Linear Accelerator with BEAMnrc and DOSXYZnrc Code.

Authors:  Keyvan Jabbari; Hossein Saberi Anvar; Mohammad Bagher Tavakoli; Alireza Amouheidari
Journal:  J Med Signals Sens       Date:  2013-07

6.  A method to improve accuracy and precision of water surface identification for photon depth dose measurements.

Authors:  J D Ververs; M J Schaefer; I Kawrakow; J V Siebers
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

7.  Experimental Validation of an Analytical Program and a Monte Carlo Simulation for the Computation of the Far Out-of-Field Dose in External Beam Photon Therapy Applied to Pediatric Patients.

Authors:  Marijke De Saint-Hubert; Finja Suesselbeck; Fabiano Vasi; Florian Stuckmann; Miguel Rodriguez; Jérémie Dabin; Beate Timmermann; Isabelle Thierry-Chef; Uwe Schneider; Lorenzo Brualla
Journal:  Front Oncol       Date:  2022-07-07       Impact factor: 5.738

8.  Calculation of organ doses from breast cancer radiotherapy: a Monte Carlo study.

Authors:  Theocharis Berris; Michael Mazonakis; John Stratakis; Antonios Tzedakis; Anastasia Fasoulaki; John Damilakis
Journal:  J Appl Clin Med Phys       Date:  2013-01-07       Impact factor: 2.102