Literature DB >> 17495270

Success, safety, and efficacy of implantation of diamond-like carbon-coated stents.

Anastasios Salahas1, Antonios Vrahatis, Ilias Karabinos, Ioannis Antonellis, Georgios Ifantis, Isidoros Gavaliatsis, Prodromos Anthopoulos, Antonios Tavernarakis.   

Abstract

The aim of this study was to evaluate safety and clinically defined efficacy of the implantation of a new stent coated with diamond-like carbon (DLC stent), in a group of patients who underwent percutaneous transluminal coronary revascularization procedures in two hemodynamic centers. This study was an observational prospective nonrandomized study that included 196 patients with a total of 236 significant de novo atheromatous coronary lesions, in which 245 DLC stents were implanted. The primary end point of this study was a composite of major cardiovascular events (death or acute myocardial infarction with or without Q) and need for target lesion revascularization (TLR) or target vessel revascularization (TVR) procedure during the first 48 hours and at 6 months after the DLC stent implantation. All patients had a myocardial perfusion imaging study with Tl(201) at 6 months after DLC stent implantation. Only patients with a myocardial perfusion imaging study indicative of myocardial ischemia were then submitted for a new coronary angiogram. No major cardiovascular event or emergency TVR occurred during hospitalization. At 6-month follow-up no major cardiovascular event occurred either, whereas the rate for TLR was 5.6% and that for TVR was 7.65%. This preliminary study provides enough clinical evidence that implantation of intracoronary bare metal stents coated with diamond-like carbon is associated with high success rates, safety, and efficacy, both in the hospital and at the 6-month follow-up after the interventional procedure.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17495270     DOI: 10.1177/0003319707300360

Source DB:  PubMed          Journal:  Angiology        ISSN: 0003-3197            Impact factor:   3.619


  4 in total

1.  Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model.

Authors:  J H Kim; J H Shin; D H Shin; M-W Moon; K Park; T-H Kim; K M Shin; Y H Won; D K Han; K-R Lee
Journal:  Br J Radiol       Date:  2011-03       Impact factor: 3.039

2.  In Vitro Biodegradation of a-C:H:SiOx Films on Ti-6Al-4V Alloy.

Authors:  Alexander Grenadyorov; Andrey Solovyev; Konstantin Oskomov; Ekaterina Porokhova; Konstantin Brazovskii; Anna Gorokhova; Temur Nasibov; Larisa Litvinova; Igor Khlusov
Journal:  Materials (Basel)       Date:  2022-06-15       Impact factor: 3.748

3.  Load-bearing biomedical applications of diamond-like carbon coatings - current status.

Authors:  Esa Alakoski; Veli-Matti Tiainen; Antti Soininen; Yrjö T Konttinen
Journal:  Open Orthop J       Date:  2008-03-26

Review 4.  Recent Advances in Manufacturing Innovative Stents.

Authors:  Natalia Beshchasna; Muhammad Saqib; Honorata Kraskiewicz; Łukasz Wasyluk; Oleg Kuzmin; Oana Cristina Duta; Denisa Ficai; Zeno Ghizdavet; Alexandru Marin; Anton Ficai; Zhilei Sun; Vladimir F Pichugin; Joerg Opitz; Ecaterina Andronescu
Journal:  Pharmaceutics       Date:  2020-04-13       Impact factor: 6.321

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.