Literature DB >> 17493376

Laparoscopic entry: a review of techniques, technologies, and complications.

George A Vilos, Artin Ternamian, Jeffrey Dempster, Philippe Y Laberge.   

Abstract

OBJECTIVE: To provide clinical direction, based on the best evidence available, on laparoscopic entry techniques and technologies and their associated complications. OPTIONS: The laparoscopic entry techniques and technologies reviewed in formulating this guideline include the classic pneumoperitoneum (Veress/trocar), the open (Hasson), the direct trocar insertion, the use of disposable shielded trocars, radially expanding trocars, and visual entry systems. OUTCOMES: Implementation of this guideline should optimize the decision-making process in choosing a particular technique to enter the abdomen during laparoscopy. EVIDENCE: English-language articles from Medline, PubMed, and the Cochrane Database published before the end of September 2005 were searched, using the key words laparoscopic entry, laparoscopy access, pneumoperitoneum, Veress needle, open (Hasson), direct trocar, visual entry, shielded trocars, radially expanded trocars, and laparoscopic complications. VALUES: The quality of evidence was rated using the criteria described in the Report of the Canadian Task Force on the Periodic Health Examination. RECOMMENDATIONS AND SUMMARY STATEMENT: 1. Left upper quadrant (LUQ, Palmer's) laparoscopic entry should be considered in patients with suspected or known periumbilical adhesions or history or presence of umbilical hernia, or after three failed insufflation attempts at the umbilicus. (II-2 A) Other sites of insertion, such as transuterine Veress CO(2) insufflation, may be considered if the umbilical and LUQ insertions have failed or have been considered and are not an option. (I-A) 2. The various Veress needle safety tests or checks provide very little useful information on the placement of the Veress needle. It is therefore not necessary to perform various safety checks on inserting the Veress needle; however, waggling of the Veress needle from side to side must be avoided, as this can enlarge a 1.6 mm puncture injury to an injury of up to 1 cm in viscera or blood vessels. (II-1 A) 3. The Veress intraperitoneal (VIP-pressure </= 10 mm Hg) is a reliable indicator of correct intraperitoneal placement of the Veress needle; therefore, it is appropriate to attach the CO(2) source to the Veress needle on entry. (II-1 A) 4. Elevation of the anterior abdominal wall at the time of Veress or primary trocar insertion is not routinely recommended, as it does not avoid visceral or vessel injury. (II-2 B) 5. The angle of the Veress needle insertion should vary according to the BMI of the patient, from 45 degrees in non-obese women to 90 degrees in obese women. (II-2 B) 6. The volume of CO(2) inserted with the Veress needle should depend on the intra-abdominal pressure. Adequate pneumoperitoneum should be determined by a pressure of 20 to 30 mm Hg and not by predetermined CO(2) volume. (II-1 A) 7. In the Veress needle method of entry, the abdominal pressure may be increased immediately prior to insertion of the first trocar. The high intraperitoneal (HIP-pressure) laparoscopic entry technique does not adversely affect cardiopulmonary function in healthy women. (II-1 A) 8. The open entry technique may be utilized as an alternative to the Veress needle technique, although the majority of gynaecologists prefer the Veress entry. There is no evidence that the open entry technique is superior to or inferior to the other entry techniques currently available. (II-2 C) 9. Direct insertion of the trocar without prior pneumoperitoneum may be considered as a safe alternative to Veress needle technique. (II-2) 10. Direct insertion of the trocar is associated with less insufflation-related complications such as gas embolism, and it is a faster technique than the Veress needle technique. (I) 11. Shielded trocars may be used in an effort to decrease entry injuries. There is no evidence that they result in fewer visceral and vascular injuries during laparoscopic access. (II-B) 12. Radially expanding trocars are not recommended as being superior to the traditional trocars. They do have blunt tips that may provide some protection from injuries, but the force required for entry is significantly greater than with disposable trocars. (I-A) 13. The visual entry cannula system may represent an advantage over traditional trocars, as it allows a clear optical entry, but this advantage has not been fully explored. The visual entry cannula trocars have the advantage of minimizing the size of the entry wound and reducing the force necessary for insertion. Visual entry trocars are non-superior to other trocars since they do not avoid visceral and vascular injury. (2 B).

Entities:  

Mesh:

Year:  2007        PMID: 17493376     DOI: 10.1016/S1701-2163(16)35496-2

Source DB:  PubMed          Journal:  J Obstet Gynaecol Can        ISSN: 1701-2163


  61 in total

1.  Anatomical changes due to pneumoperitoneum analyzed by MRI: an experimental study in pigs.

Authors:  F M Sánchez-Margallo; J L Moyano-Cuevas; R Latorre; J Maestre; L Correa; J B Pagador; L F Sánchez-Peralta; J A Sánchez-Margallo; J Usón-Gargallo
Journal:  Surg Radiol Anat       Date:  2010-12-22       Impact factor: 1.246

Review 2.  Abdominal anatomy in the context of port placement and trocars.

Authors:  Ibrahim Alkatout; Liselotte Mettler; Nicolai Maass; Günter-Karl Noé; Mohamed Elessawy
Journal:  J Turk Ger Gynecol Assoc       Date:  2015-11-02

3.  Laparoscopic ventral hernia repair.

Authors:  W Scott Melvin; David Renton
Journal:  World J Surg       Date:  2011-07       Impact factor: 3.352

4.  Functional luminal imaging probe geometric and histomorphologic analysis of abdominal wall wound induced by different trocars in pigs.

Authors:  Jingbo Zhao; Donghua Liao; Barry P McMahon; Deidre O'Donovan; Rich Schiretz; Russell Heninrich; Hans Gregersen
Journal:  Surg Endosc       Date:  2008-09-24       Impact factor: 4.584

5.  Creation of pneumoperitoneum using a bladed optical trocar in morbidly obese patients: technique and results.

Authors:  Paolo Bernante; Mirto Foletto; Antonio Toniato
Journal:  Obes Surg       Date:  2008-05-14       Impact factor: 4.129

6.  Development of angle information system to facilitate the adjustment of needle-holding posture.

Authors:  Yang Cao; Li Liu; Satoshi Miura; Masaki Seki; Yo Kobayashi; Kazuya Kawamura; Masakatsu G Fujie
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-05-29       Impact factor: 2.924

Review 7.  Blunt versus bladed trocars in laparoscopic surgery: a systematic review and meta-analysis of randomized trials.

Authors:  Stavros A Antoniou; George A Antoniou; Oliver O Koch; Rudolph Pointner; Frank A Granderath
Journal:  Surg Endosc       Date:  2013-02-07       Impact factor: 4.584

8.  Technical modifications in the robotic-assisted surgical approach for gynaecologic operations.

Authors:  Frederik Peeters; Zvi Vaknin; Susie Lau; Claire Deland; Sonya Brin; Walter H Gotlieb
Journal:  J Robot Surg       Date:  2010-11-10

9.  Complications in colorectal surgery: risk factors and preventive strategies.

Authors:  Philipp Kirchhoff; Pierre-Alain Clavien; Dieter Hahnloser
Journal:  Patient Saf Surg       Date:  2010-03-25

10.  Laparoscopic ventral hernia repair during pregnancy.

Authors:  P Y Wai; J A Ruby; K A Davis; A C Roberts; K E Roberts
Journal:  Hernia       Date:  2009-03-12       Impact factor: 4.739

View more