The diagnostic value of adenosine stress-contrast echocardiography for diagnosis of coronary artery disease in hypertensive patients: comparison to Tl-201 single-photon emission computed tomography.

Constadina Aggeli1, Euaggelia Christoforatou, Georgios Giannopoulos, Georgios Roussakis, Christos Kokkinakis, John Barbetseas, Charalambos Vlachopoulos, Christodoulos Stefanadis.   

Abstract

BACKGROUND: The use of the vasodilating agent adenosine as stressor in conjunction with myocardial contrast echocardiography has not been extensively evaluated in hypertensive patients. Our aim was to evaluate the diagnostic value of adenosine myocardial contrast echocardiography (MCE) in comparison to single-photon emission computed tomography (SPECT), with reference to angiographic findings, in a hypertensive population.
METHODS: Fifty hypertensive subjects, treated with standard antihypertensive treatment, were submitted to adenosine stress MCE, adenosine SPECT, and coronary angiography within a 1-month period, without any intervening events.
RESULTS: Sensitivity, specificity, and accuracy were 88%, 89%, 88% for MCE and 80%, 94%, 85% for SPECT, respectively (P = not significant). In the analysis by coronary territory, it appears that MCE and SPECT are both more accurate in detecting lesions of the anterior than of the posterior coronary system, as suggested by the good concordance to angiography results in the left anterior descending artery territory (k = 0.640 and 0.671, respectively). Agreement with angiographic findings was moderate for the right coronary artery (k = 0.561 and 0.539, respectively), whereas left circumflex artery lesions were more accurately detected by MCE than by SPECT (k = 0.533 and 0.400, respectively), that is, MCE appears to be superior in the left circumflex artery territory.
CONCLUSIONS: In hypertensive patients, adenosine MCE has similar overall diagnostic accuracy with SPECT for assessment of coronary artery disease but is superior in the left circumflex artery territory.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17485016     DOI: 10.1016/j.amjhyper.2006.10.003

Source DB:  PubMed          Journal:  Am J Hypertens        ISSN: 0895-7061            Impact factor:   2.689


  7 in total

1.  Diagnostic accuracy of contrast echocardiography during adenosine stress for detection of abnormal myocardial perfusion: a prospective comparison with technetium-99 m sestamibi single-photon emission computed tomography.

Authors:  Sahar S Abdelmoneim; Mathieu Bernier; Abhijeet Dhoble; Stuart Moir; Mary E Hagen; Sue Ann C Ness; Patricia A Pellikka; Samir S Abdel-Kader; Sharon L Mulvagh
Journal:  Heart Vessels       Date:  2010-03-26       Impact factor: 2.037

2.  Myocardial perfusion scintigraphy and echocardiography for detecting coronary artery disease in hypertensive patients: a meta-analysis.

Authors:  Paola Gargiulo; Mario Petretta; Dario Bruzzese; Alberto Cuocolo; Maria Prastaro; Carmen D'Amore; Enrico Vassallo; Gianluigi Savarese; Caterina Marciano; Stefania Paolillo; Pasquale Perrone Filardi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-04       Impact factor: 9.236

3.  Limitations and potential clinical application on contrast echocardiography.

Authors:  Elisa Modonesi; Manrico Balbi; Gian Paolo Bezante
Journal:  Curr Cardiol Rev       Date:  2010-02

4.  Stress echocardiography with contrast for the diagnosis of coronary artery disease: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2010-06-01

5.  Single photon emission computed tomography for the diagnosis of coronary artery disease: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2010-06-01

6.  Use of contrast agents with echocardiography in patients with suboptimal echocardiography: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2010-06-01

Review 7.  Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis.

Authors:  Marcus C de Jong; Tessa S S Genders; Robert-Jan van Geuns; Adriaan Moelker; M G Myriam Hunink
Journal:  Eur Radiol       Date:  2012-04-19       Impact factor: 5.315