Literature DB >> 17482111

Pullout resistance of thoracic extrapedicular screws used as a salvage procedure.

K Zafer Yüksel1, Mark S Adams, Robert H Chamberlain, Mark Potocnjak, Sung Chan Park, Volker K H Sonntag, Neil R Crawford.   

Abstract

BACKGROUND CONTEXT: Extrapedicular screws are placed more laterally than intrapedicular screws and pass through the transverse process or rib head before entering the vertebral body. These screws are sometimes placed to salvage failed pedicle screws, but the change in pullout resistance of extrapedicular screws after salvage has not been quantified.
PURPOSE: To quantify the pullout resistance of thoracic extrapedicular screws compared with intrapedicular screws and the pullout resistance of newly inserted screws compared with extrapedicular screws used as salvage for failed intrapedicular screws. STUDY
DESIGN: In vitro paired comparison of screw pullout resistance in isolated thoracic vertebrae.
METHODS: Tapered monoaxial pedicle screws were inserted in the left or right pedicle of 11 human cadaveric thoracic vertebrae. An extrapedicular screw was inserted on the contralateral side. Both screws were pulled out axially at 0.5 mm/s using a servohydraulic test frame while applied load was recorded. Then a fresh extrapedicular screw was inserted as a salvage screw on the intrapedicular screw side and pulled out.
RESULTS: In uncompromised vertebrae, the pullout strength of extrapedicular screws was 80+/-32% of that of intrapedicular screws (p=.073, repeated-measures one-way analysis of variance/Tukey). Salvage screws restored pullout strength to 65+/-30% of that of intrapedicular screws (p=.003).
CONCLUSIONS: Extrapedicular screws provided comparable but slightly lower pullout resistance to intrapedicular screws in uncompromised vertebrae. They are therefore a feasible salvage technique when a compromised pedicle precludes reinsertion of an intrapedicular screw, but the salvage screw is significantly weaker than the original screw.

Entities:  

Mesh:

Year:  2006        PMID: 17482111     DOI: 10.1016/j.spinee.2005.12.007

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  7 in total

1.  Comparison of pullout strength of the thoracic pedicle screw between intrapedicular and extrapedicular technique: a meta-analysis and literature review.

Authors:  Hua Wang; Huafeng Wang; Shilabant Sen Sribastav; Fubiao Ye; Chunxiang Liang; Zemin Li; Jianru Wang; Hui Liu; Xin Wang; Zhaomin Zheng
Journal:  Int J Clin Exp Med       Date:  2015-12-15

2.  Accuracy of thoracic pedicle screw placement in adolescent patients with severe spinal deformities: a retrospective study comparing drill guide template with free-hand technique.

Authors:  Yue Pan; G H Lü; Lei Kuang; Bing Wang
Journal:  Eur Spine J       Date:  2017-12-12       Impact factor: 3.134

3.  Complications associated with thoracic pedicle screws in spinal deformity.

Authors:  Gang Li; Guohua Lv; Peter Passias; Michal Kozanek; Umesh S Metkar; Zhongjun Liu; Kirkham B Wood; Lubos Rehak; Youwen Deng
Journal:  Eur Spine J       Date:  2010-03-17       Impact factor: 3.134

4.  Pedicular and extrapedicular morphometric analysis in the korean population : computed tomographic assessment relevance to pedicle and extrapedicle screw fixation in the thoracic spine.

Authors:  Jun-Hak Kim; Gyeong-Mi Choi; In-Bok Chang; Sung-Ki Ahn; Joon-Ho Song; Hyun-Chul Choi
Journal:  J Korean Neurosurg Soc       Date:  2009-09-30

5.  A comparative study on the accuracy of pedicle screw placement assisted by personalized rapid prototyping template between pre- and post-operation in patients with relatively normal mid-upper thoracic spine.

Authors:  Yong Hu; Zhen-Shan Yuan; William Ryan Spiker; Wei-Xin Dong; Xiao-Yang Sun; Jian-Bing Yuan; Jiao Zhang; Bingke Zhu
Journal:  Eur Spine J       Date:  2016-03-28       Impact factor: 3.134

6.  Pullout strength of misplaced pedicle screws in the thoracic and lumbar vertebrae - A cadaveric study.

Authors:  Shyam K Saraf; Ravindra P Singh; Vakil Singh; Ashish Varma
Journal:  Indian J Orthop       Date:  2013-05       Impact factor: 1.251

7.  Biomechanical Comparison of Pedicle Screw Augmented with Different Volumes of Polymethylmethacrylate in Osteoporotic and Severely Osteoporotic Synthetic Bone Blocks in Primary Implantation: An Experimental Study.

Authors:  Da Liu; Xiao-jun Zhang; Dong-fa Liao; Jiang-jun Zhou; Zhi-qiang Li; Bo Zhang; Cai-ru Wang; Wei Lei; Xia Kang; Wei Zheng
Journal:  Biomed Res Int       Date:  2016-01-17       Impact factor: 3.411

  7 in total