Cardiac image fusion from stand-alone SPECT and CT: clinical experience.

Oliver Gaemperli1, Tiziano Schepis, Ines Valenta, Lars Husmann, Hans Scheffel, Victor Duerst, Franz R Eberli, Thomas F Luscher, Hatem Alkadhi, Philipp A Kaufmann.   

Abstract

UNLABELLED: Myocardial perfusion imaging with SPECT (SPECT-MPI) and 64-slice CT angiography (CTA) are both established techniques for the noninvasive evaluation of coronary artery disease (CAD). Three-dimensional (3D) SPECT/CT image fusion may offer an incremental diagnostic value by integrating both sets of information. We report our first clinical experiences with fused 3D SPECT/CT in CAD patients.
METHODS: Thirty-eight consecutive patients with at least 1 perfusion defect on SPECT-MPI (1-d adenosine stress/rest SPECT with (99m)Tc-tetrofosmin) and 64-slice CTA were included. 3D volume-rendered fused SPECT/CT images were generated and compared with the findings from the side-by-side analysis with regard to coronary lesion interpretation by assigning the perfusion defects to their corresponding coronary lesion.
RESULTS: The fused SPECT/CT images added information on pathophysiologic lesion severity in 27 coronary stenoses (22%) of 12 patients (29%) (P<0.001). Among 40 equivocal lesions on side-by-side analysis, the fused interpretation confirmed hemodynamic significance in 14 lesions and excluded functional relevance in 10 lesions. In 3 lesions, assignment of perfusion defect and coronary lesion appeared to be reliable on side-by-side analysis but proved to be inaccurate on fused interpretation. Added diagnostic information by SPECT/CT was more commonly found in patients with stenoses of small vessels (P=0.004) and involvement of diagonal branches (P=0.01).
CONCLUSION: In addition to being intuitively convincing, 3D SPECT/CT fusion images in CAD may provide added diagnostic information on the functional relevance of coronary artery lesions.

Entities:  

Mesh:

Year:  2007        PMID: 17475956     DOI: 10.2967/jnumed.106.037606

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  64 in total

1.  Downstream resource utilization following hybrid cardiac imaging with an integrated cadmium-zinc-telluride/64-slice CT device.

Authors:  Michael Fiechter; Jelena R Ghadri; Mathias Wolfrum; Silke M Kuest; Aju P Pazhenkottil; Rene N Nkoulou; Bernhard A Herzog; Cathérine Gebhard; Tobias A Fuchs; Oliver Gaemperli; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-12-06       Impact factor: 9.236

2.  Combined anatomical and functional imaging using coronary CT angiography and myocardial perfusion SPECT in symptomatic adults with abnormal origin of a coronary artery.

Authors:  C Uebleis; M Groebner; F von Ziegler; A Becker; C Rischpler; R Tegtmeyer; C Becker; S Lehner; A R Haug; P Cumming; P Bartenstein; W M Franz; M Hacker
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-07       Impact factor: 2.357

3.  Automatic alignment of myocardial perfusion PET and 64-slice coronary CT angiography on hybrid PET/CT.

Authors:  Ryo Nakazato; Damini Dey; Erick Alexánderson; Aloha Meave; Moisés Jiménez; Edgar Romero; Rodrigo Jácome; Marco Peña; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2012-03-15       Impact factor: 5.952

4.  Quantitative Nuclear Cardiology: we are almost there!

Authors:  Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2012-03-31       Impact factor: 5.952

5.  MR/CT image fusion of the spine after spondylodesis: a feasibility study.

Authors:  C A Karlo; I Steurer-Dober; M Leonardi; C W A Pfirrmann; M Zanetti; J Hodler
Journal:  Eur Spine J       Date:  2010-05-15       Impact factor: 3.134

Review 6.  Secondary revascularization after CABG surgery.

Authors:  Javier Escaned
Journal:  Nat Rev Cardiol       Date:  2012-07-10       Impact factor: 32.419

7.  Quantitation in gated perfusion SPECT imaging: the Cedars-Sinai approach.

Authors:  Guido Germano; Paul B Kavanagh; Piotr J Slomka; Serge D Van Kriekinge; Geoff Pollard; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

8.  "Mismatch" in regional myocardial perfusion defects during exercise and pharmacologic vasodilation: a noninvasive marker of epicardial vasomotor dysfunction?

Authors:  Thomas H Schindler; Heinrich H Schelbert
Journal:  J Nucl Cardiol       Date:  2007 Nov-Dec       Impact factor: 5.952

9.  Hybrid cardiac imaging: more than the sum of its parts?

Authors:  Oliver Gaemperli; Philipp A Kaufmann
Journal:  J Nucl Cardiol       Date:  2008 Jan-Feb       Impact factor: 5.952

10.  Incremental value of combining 64-slice computed tomography angiography with stress nuclear myocardial perfusion imaging to improve noninvasive detection of coronary artery disease.

Authors:  Akira Sato; Toshihiro Nozato; Hiroyuki Hikita; Shinsuke Miyazaki; Yoshihide Takahashi; Taishi Kuwahara; Atsushi Takahashi; Michiaki Hiroe; Kazutaka Aonuma
Journal:  J Nucl Cardiol       Date:  2009-09-24       Impact factor: 5.952