Literature DB >> 17467027

Regional mechanical properties and stress analysis of the human anterior lens capsule.

R M Pedrigi1, G David, J Dziezyc, J D Humphrey.   

Abstract

The lens capsule of the eye functions, in part, as a deformable support through which the ciliary body applies tractions that can alter lens curvature and corresponding refractive power during the process of accommodation. Although it has long been recognized that characterization of the mechanical properties of the lens capsule is fundamental to understanding this physiologic process as well as clinical interventions, prior data have been limited by one-dimensional testing of excised specimens despite the existence of multiaxial loading in vivo. In this paper, we employ a novel experimental approach to study in situ the regional, multiaxial mechanical behavior of both normal and diabetic human anterior lens capsules. Furthermore, we use these data to calculate material parameters in a nonlinear stress-strain relation via a custom sub-domain inverse finite element method (FEM). These parameters are then used to predict capsular stresses in response to imposed loads using a forward FEM model. Our results for both normal and diabetic human eyes show that the anterior lens capsule exhibits a nonlinear pseudoelastic behavior over finite strains that is typical of soft tissues, and that strains are principal relative to meridional and circumferential directions. Experimental data and parameter estimation suggest further that the capsule is regionally anisotropic, with the circumferential direction becoming increasingly stiffer than the meridional direction towards the equator. Although both normal and diabetic lens capsules exhibited these general characteristic behaviors, diabetic capsules were significantly stiffer at each distension. Finally, the forward FEM model predicted a nearly uniform, equibiaxial stress field during normalcy that will be perturbed by cataract surgery. Such mechanical perturbations may be an underlying modulator of the sustained errant epithelial cell behavior that is observed well after cataract surgery and may ultimately contribute to opacification of the posterior lens capsule.

Entities:  

Mesh:

Year:  2007        PMID: 17467027     DOI: 10.1016/j.visres.2007.03.014

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  13 in total

1.  Primate lens capsule elasticity assessed using Atomic Force Microscopy.

Authors:  Noël M Ziebarth; Esdras Arrieta; William J Feuer; Vincent T Moy; Fabrice Manns; Jean-Marie Parel
Journal:  Exp Eye Res       Date:  2011-03-21       Impact factor: 3.467

2.  An improved panoramic digital image correlation method for vascular strain analysis and material characterization.

Authors:  K Genovese; Y-U Lee; A Y Lee; J D Humphrey
Journal:  J Mech Behav Biomed Mater       Date:  2012-12-06

3.  On a Class of Admissible Constitutive Behaviors in Free-Floating Engineered Tissues.

Authors:  D D Simon; J D Humphrey
Journal:  Int J Non Linear Mech       Date:  2012-03-01       Impact factor: 2.985

4.  Impact of heparan sulfate chains and sulfur-mediated bonds on the mechanical properties of bovine lens capsule.

Authors:  L B Dyksterhuis; L D Dyksterhuis; J F White; M Hickey; N Kirby; S Mudie; A Hawley; A Vashi; J Nigro; J A Werkmeister; J A M Ramshaw
Journal:  Biophys J       Date:  2011-05-04       Impact factor: 4.033

5.  Automatic Segmentation of Mechanically Inhomogeneous Tissues Based on Deformation Gradient Jump.

Authors:  Colleen M Witzenburg; Rohit Y Dhume; Spencer P Lake; Victor H Barocas
Journal:  IEEE Trans Med Imaging       Date:  2015-07-07       Impact factor: 10.048

6.  A biomechanical model for evaluating the performance of accommodative intraocular lenses.

Authors:  Kurt A Ameku; Ryan M Pedrigi
Journal:  J Biomech       Date:  2022-03-18       Impact factor: 2.789

7.  A nonlinear anisotropic inverse method for computational dissection of inhomogeneous planar tissues.

Authors:  Colleen M Witzenburg; Victor H Barocas
Journal:  Comput Methods Biomech Biomed Engin       Date:  2016-05-02       Impact factor: 1.763

Review 8.  The lens capsule.

Authors:  Brian P Danysh; Melinda K Duncan
Journal:  Exp Eye Res       Date:  2008-08-16       Impact factor: 3.467

9.  Computational Simulation of Scleral Buckling Surgery for Rhegmatogenous Retinal Detachment: On the Effect of the Band Size on the Myopization.

Authors:  Elena Lanchares; María A Del Buey; José A Cristóbal; Begoña Calvo; Francisco J Ascaso; Mauro Malvè
Journal:  J Ophthalmol       Date:  2016-06-20       Impact factor: 1.909

10.  Altered stress field of the human lens capsule after cataract surgery.

Authors:  Caleb C Berggren; Kurt A Ameku; Ryan M Pedrigi
Journal:  J Biomech       Date:  2020-11-10       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.