Auditory-evoked potentials in bispectral index-guided anaesthesia for cardiac surgery.

T Musialowicz1, M Niskanen, H Yppärilä-Wolters, M Pöyhönen, O Pitkänen, M Hynynen.   

Abstract

BACKGROUND AND
OBJECTIVE: Midlatency auditory-evoked potentials, as measures of the anaesthetic state, were evaluated at similar levels of bispectral index in cardiac surgical patients maintained with either propofol or isoflurane anaesthesia.
METHODS: Twenty-four patients were randomly allocated to anaesthesia with propofol (n = 12) or isoflurane (n = 12). Bispectral index was maintained below 60 during surgery. Auditory-evoked potentials were collected before induction of anaesthesia, 10 min after intubation, 30 min after sternotomy, during cardiopulmonary bypass at the time of cross-clamping of the aorta and during stable mild hypothermia, after de-clamping of the aorta, and after the operation.
RESULTS: At the pre-determined time points, bispectral index values showed comparable depth of hypnosis in both groups. The latency of the Nb component of midlatency auditory-evoked potentials was significantly increased in the isoflurane group after intubation (P < 0.001) and that of both the Nb and the Pa components after sternotomy (P < 0.001) compared with the propofol group. No differences between the groups were detected with respect to haemodynamic variables. No patient reported recall of intraoperative events.
CONCLUSION: After intubation and surgical stimulation, when bispectral index was at a constant level, there was a difference in the Nb and Pa components of the midlatency auditory-evoked potentials between the two anaesthetic regimens, indicating a distinction in the state of anaesthesia. Our results suggest that the parallel use of these two electrophysiological methods can show differences in the components of anaesthesia between various anaesthesia methods in cardiac surgical patients.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17462117     DOI: 10.1017/S0265021507000403

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  4 in total

1.  Comparison of spectral entropy and BIS VISTA™ monitor during general anesthesia for cardiac surgery.

Authors:  Tadeusz Musialowicz; Pasi Lahtinen; Otto Pitkänen; Jouni Kurola; Ilkka Parviainen
Journal:  J Clin Monit Comput       Date:  2011-04-22       Impact factor: 2.502

2.  Composite-, plain-auditory evoked potentials index and bispectral index to measure the effects of sevoflurane.

Authors:  Tomoki Nishiyama
Journal:  J Clin Monit Comput       Date:  2013-02-17       Impact factor: 2.502

3.  Additive Effect on Survival of Anaesthetic Cardiac Protection and Remote Ischemic Preconditioning in Cardiac Surgery: A Bayesian Network Meta-Analysis of Randomized Trials.

Authors:  Alberto Zangrillo; Mario Musu; Teresa Greco; Ambra Licia Di Prima; Andrea Matteazzi; Valentina Testa; Pasquale Nardelli; Daniela Febres; Fabrizio Monaco; Maria Grazia Calabrò; Jun Ma; Gabriele Finco; Giovanni Landoni
Journal:  PLoS One       Date:  2015-07-31       Impact factor: 3.240

4.  Composite auditory evoked potentials index is not a good indicator of depth of anesthesia in propofol-fentanyl anesthesia: Randomized comparative study.

Authors:  Tomoki Nishiyama
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.